5.4.4.4
Summer switch-off
Factory preset:
20°C
Setting range
OFF, 10...30°C
NOTE
This function is only effective in operating mode automatic.
Function:
This parameter determines the end of the heating season based on the outside
temperature.
When the summer switch-off mode is active, it is indicated on the basic display by a
sunshade symbol.
5.4.4.5
Reset Parameter
With the Parameter
RESET
you can restore the factory settings in case of settings
made by mistake in the parameter menus.
Important:
Reset is to be performed only if all the personalized set values are to be replaced by
the factory settings!
Reset:
With the reset indicator flashing (
RESET
) the reset-ready indicator (
SET
) will flash
when the rotary-push button is pressed briefly.
A reset will be performed when the rotary-push button is pressed for approx. 5
seconds.
Once the parameter settings have been reset, the device will jump back to the first
parameter on menu level
SYSTEM
.
5.4.5
DHW level
This level comprises all parameters which are necessary to program the DHW circuit
with the exception of the operating time programs.
Notes:
This level can only be accessed if in the level
Hydraulic
the
Parameter 2 (DHW charging pump) was et to OFF by the heating
specialist..
5.4.5.1
Hot water economy temperature
Factory preset:
40°C
Setting range:
10°C...Setting value DHW normal temperature (
§
)
Function:
This parameter determines the temperature in the domestic hot water heater
between the heating cycles in automatic mode.
Note:
If a DHW thermostat is used to determine the water heater temperature, this
parameter is skipped.
Содержание Controller Series
Страница 2: ......
Страница 8: ...EbV Product documentation THETA NORM UNIT VI...
Страница 10: ...EbV Product documentation THETA NORM UNIT 1 2...
Страница 16: ...EbV Product documentation THETA NORM UNIT 2 6...
Страница 18: ...EbV Product documentation THETA NORM UNIT 3 2...
Страница 20: ...EbV Product documentation THETA NORM UNIT 4 2...
Страница 70: ...EbV Product documentation THETA NORM UNIT 5 50...
Страница 78: ...EbV Product documentation THETA NORM UNIT 6 8...
Страница 162: ...EbV Product documentation THETA NORM UNIT 10 10...
Страница 170: ...EbV Product documentation THETA NORM UNIT 11 8...
Страница 192: ...PD_THETA NURS_EbV_GB_0460017001_0612 23...