![Rotex Controller Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/rotex/controller-series/controller-series_product-documentation_1491112033.webp)
EbV
Product documentation THETA NORM/UNIT
5-13
5.1.2.7.2
Operating states
After entering of the information level by means of the information key
¤
, a query of all available operating
statuses such as counter numbers, capacities etc. can be made by turning the rotary pushbutton anti-
clockwise.
Ambient temper.
Mixing circuit 2
Nominal/actual value
Remote control necessary
(..33..)
Thermostat function
Unmixed heating circuit
THERMOSTAT
HC
Room thermostat function
activated
OFF = no room temperature limit
(..2..)
Thermostat function
Mixing circuit 1
THERMOSTAT
MC-1
Room thermostat function
activated
OFF = no room temperature limit
(..3..)
Thermostat function
Mixing circuit 2
THERMOSTAT
MC-2
Room thermostat function
activated
OFF = no room temperature limit
(..33..)
Boiler temp. solid fuel
Actual value
Solid fuel charging pump at
variable output
(..VV..)
Buffer temp. Solid fuel
boiler
Actual value
Solid fuel charging pump at
variable output, corresponds to
SBUS or BUSF, according to
configuration.
(..VV..)
Upper buffer sensor
Nominal/actual value
Buffer charging pump at var. output
(..VV..)
Lower buffer sensor
Nominal/actual value
Buffer sensor 2 at var. input
(..VV..)
Solar panel sensor
Actual value
Solar pump at var. output
(..VV..)
(..VV..)
Solar tank
Actual value
Solar pump at var. output
(..VV..)
Solar panel return flow
sensor
Actual value
Solar pump at var. output
Return flow sensor at var. input
(..VV..)
Solar tank
changeover
Actual value
Solar valve activated
(..VV..)
Information
Display
(Example)
Function
Application
Status
Unmixed circuit
AUTO-P1 ECO
HC ON
Operating mode/
é
-program/mode
status of heating pump
(..2..)
Status
Mixing circuit 1
AUTO-P1 ECO
MC-1 ON
Operating mode/
é
-program/mode
status of heating pump
(..3..)
Status actuator
Mix.valve-1
MIX.VALVE-1
OPEN
Display of direction
OPEN-STOP-CLOS
(..3..)
Status
Mixing circuit 2
AUTO-P1 ECO
MC-2 ON
Operating mode/
é
-program/mode
status of heating pump
(..33..)
Status actuator
Mix.valve-2
MIX.VALVE-2
STOP
Display of direction
OPEN-STOP-CLOS
(..33..)
INFORMATION
Displayed value
Remarks
Application
Содержание Controller Series
Страница 2: ......
Страница 8: ...EbV Product documentation THETA NORM UNIT VI...
Страница 10: ...EbV Product documentation THETA NORM UNIT 1 2...
Страница 16: ...EbV Product documentation THETA NORM UNIT 2 6...
Страница 18: ...EbV Product documentation THETA NORM UNIT 3 2...
Страница 20: ...EbV Product documentation THETA NORM UNIT 4 2...
Страница 70: ...EbV Product documentation THETA NORM UNIT 5 50...
Страница 78: ...EbV Product documentation THETA NORM UNIT 6 8...
Страница 162: ...EbV Product documentation THETA NORM UNIT 10 10...
Страница 170: ...EbV Product documentation THETA NORM UNIT 11 8...
Страница 192: ...PD_THETA NURS_EbV_GB_0460017001_0612 23...