LCAC R32 Series
86
Service manual
1.3.3.2 Indoor Fan Running Guidelines
In heating mode, indoor fan speed can be set at high, medium, low, or auto fan, and the anti-cold-wind function is
preferential.
When the compressor is running, The indoor fan is regulated as illustrated as in the following figure:
24~60K:
T4
E
D
C
B
A
A+
Setting fan
speed
Actual fan speed
H
(
=H
)
H+(H+=H+G)
M(M=M)
M+(M+=M+Z)
L(L=L)
L+(L+=L+D)
H-
(
H-=H-G)
M-(M-=M-Z)
L-(L-=L-D)
T1-Td
L
H
M
-
When the indoor temp reaches the present temperature, the compressor stops and the indoor fan motor runs at the
minimum speed (The anti-cold-wind is valid).
The auto fan in heating mode acts as follows:
T1-Td
L
(H+-L)*0.4+L
(H+-L)*0.6+L
H+
(H+-L)*0.8+L
(H+-L)*0.6+L
(H+-L)*0.2+L
PART 5. ELECTRICAL CONTROL SYSTEM
Содержание J100Wi
Страница 1: ...LCAC R32 SERIES Tenji W Jato W Nevo W ENG Service manual ...
Страница 13: ...LCAC R32 Series 13 Service manual PART 2 INDOOR UNITS 1 5 2 Units 30 42K a Cooling b Heating ...
Страница 14: ...LCAC R32 Series 14 Service manual PART 2 INDOOR UNITS 1 5 3 Units 48 55K a Cooling b Heating ...
Страница 18: ...LCAC R32 Series 18 Service manual PART 2 INDOOR UNITS 1 10 1 Wiring diagram for T140Wi T160Wi ...
Страница 44: ...LCAC R32 Series 44 Service manual PART 2 INDOOR UNITS 3 10 FIELD WIRING ...
Страница 49: ...LCAC R32 Series 49 Service manual PART 3 OUTDOOR UNITS 3 4 Wiring diagrams T100Wo N100Wo J100Wo ...
Страница 131: ...LCAC R32 Series 131 Service manual NOTES ...
Страница 132: ...www rotenso pl email info rotenso pl Installer stamp ...