background image

Programming Cards and Tags 

CP-R25 Hardware & Software Manual 

Page 25 

 

Serial number user cards as well as Reader configuration 
cards. 

 

Swipe reader – Used to write and read cards containing 

fingerprint templates. This tab also allows the creation of 

configuration cards for fingerprint readers. 

The AS-B01 application offers various configuration options 
including the following: 

 

Configuring the Card ID, card key and fingerprint 

enrollment separately. This is for a new MIFARE User Card. 

 

Configuring the Card ID and card key at the same time. 

This is for a previously configured MIFARE User Card. 

 

Configuring the Card ID, card key and fingerprint 
enrollment at the same time. This is for a previously 

configured MIFARE User Card. 

Once the card is configured, the Card ID and the KeyA value 
can be modified, of if required, completely wiped from the 

card. 
There is also an option to configure the Card ID, KeyA 

programmer key as well as do the fingerprint enrollment on a 
previously configured MIFARE User Card in one operation. 

5.5

 

Programming a Sector Read User Card 

The first stage of preparing a MIFARE sector read User Card is 

configuring a card ID and card KeyA value. These two 
configuration values are done simultaneously. 

To Program a MIFARE Sector Read User Card: 

1. Select 

Sector Reader

 tab. 

2. Select 

the 

Sector

 

Operation Mode

Define the 

ID Location

 using the 

Sector Number

Block 

Number

, and 

Byte Number

 fields. 

 

Note: 

If Card serial number is being used by the organization, no 
programming is available for the user card. 

 

3.  Ensure that the 

Operations

 is set to 

Program Card

Содержание Mifare CP-R25

Страница 1: ...CP R25 AS B01 Desktop MIFARE and fingerprint card programmer and Software Hardware Software Manual November 2009 ...

Страница 2: ......

Страница 3: ...ware Installation 13 4 AS B01 Software Overview and LEDs 16 4 1 Starting the Software 16 4 2 Software Overview 17 4 3 Indication LED s 18 5 Programming Cards and Tags 20 5 1 Programming Configuration Cards 21 5 2 Sector Reader Configuration Cards 22 5 3 Fingerprint Swipe Reader Configuration Cards 23 5 4 Programming User Cards or Tags 24 5 5 Programming a Sector Read User Card 25 5 6 Programming a...

Страница 4: ...g Fingerprints on a Preconfigured User Card 34 6 11Verifying fingerprint enrollment on a User Card 35 7 Global Options 36 7 1 Change Password 36 7 2 Card Overwrite 37 Appendix A Maintenance 38 Appendix B Field Descriptions 41 Appendix C Additional MIFARE Card Memory Map Information 44 Appendix D Sample Worksheets 46 Appendix E Limited Warranty 47 Appendix F Technical Support 49 ...

Страница 5: ... built for high security portability and ease of use enabling high quality MIFARE and fingerprint enrollment at a low cost The CP R25 programmer is controlled by computer using Rosslare s powerful AS B01 Programmer software package 1 2 Desktop Convenience The CP R25 is small and lightweight with a slim and attractive design It is built for convenience and portability with a USB 2 0 computer interf...

Страница 6: ...patibility The CP R25 Desktop Programmer and AS B01 software are compatible with other products including but not limited to AY W6260 and AY W6360 Read Sector smart card read write access control reader family AY Q6260 and AY Q6360 Anti vandal read sector smart card read write access control reader family AY Bx663 X 1 3 4 MIFARE Smart Card Fingerprint Swipe Sensor Family 1 5 Main Features The CP R...

Страница 7: ... Software Programs fingerprints on Users cards Programs ID data on Users cards Produces configuration cards for Rosslare MIFARE readers Performs firmware updates on supported desktop programmers Maintains a user log to provide feedback to the software user Provides password protection Indicates valid connections with Desktop Programmer ...

Страница 8: ...or Electrostatic Discharge Up to 15 kV air discharge on the sensor surface FAR False Accept Rate Actual values depends on specific user s finger usage condition and quality of enrollment Specification 0 0010 1 100000 FRR False Reject Rate Actual values depends on specific user s finger usage condition and quality of enrollment Specification 2 1 50 Electrical Specifications Operating Voltage 5V DC ...

Страница 9: ...emperature 10º to 50º C 50º to 122º F Operating Humidity 0 95 non condensing 2 2 AS B01 Software Requirements Minimum Software Requirements Operating System Windows XP SP2 Framework Microsoft NET 2 Processor 400MHz Pentium or equivalent RAM Memory 512 Mbytes Free HD space 1 Gigabyte Connection Port USB ...

Страница 10: ...d includes a USB cable and documentation Please confirm all the items listed below are received before beginning If any items are missing contact your dealer immediately One CP R25 Programmer One Male A to Male B USB Cable One Software CD Instruction Manual 3 2 CP R25 Description The following figure illustrates the CP R25 components Figure 2 CP R25 Description ...

Страница 11: ...lation open My Computer double click on the CD drive icon and then double click the AS B01 setup file Note If the Microsoft NET 2 Framework is not installed on the computer it will be installed automatically before beginning the AS B01 installation The installation package extracts the installation files After the files are extracted the Welcome to the CP R25 Setup Wizard window is displayed Figur...

Страница 12: ... click Browse The standard Windows Explorer window is displayed Navigate to and select the required folder To ensure the computer has sufficient space click Disk Cost The AS B01 Setup Disk Space window is displayed Figure 5 ASB01 Setup Disk Space Availability To close the AS B01 Setup Disk Space window click OK 5 Select the users allowed to use the program Everyone or Just me For security purposes...

Страница 13: ...ation process The Confirm Installation window is displayed Figure 6 ASB01 Setup Confirm Installation 7 Click Next to continue the installation process The Installation Complete window is displayed Figure 7 ASB01 Setup Installation Complete 8 Click Close to complete the installation process ...

Страница 14: ...eps First the AS B01 software must be operating and then the CP R25 can be connected To connect the CP R25 1 Click on the AS B01 icon on the desktop or select the program from the Rosslare folder in the Start menu The Login dialog is displayed Figure 8 AS B01 Login Dialog 2 Enter a password The default password is admin The AS B01 software Main window is displayed Make sure to change the default p...

Страница 15: ...cable end connects to PC USB host port output and the other end connects to the USB connector on the Desktop Programmer 4 Windows automatically installs the required drivers 5 The Desktop Programmer receives its power through the USB No external power supply is required On the AS B01 Main window the connection indicator at the bottom of the window changes from red to green with the description Con...

Страница 16: ... and the event log displays a disconnected message The Software can only function in demonstration mode If the indicator does not turn green and the description still indicates Disconnected after the USB cable is connected try disconnecting the USB cable from the Desktop Programmer and reconnecting it Once the indicator is green and the description is Connected the CP R25 Desktop Programmer is now...

Страница 17: ...w as well as describe the AS B01 and CP R25 LEDs 4 1 Starting the Software To start the software 1 Click on the AS B01 icon on the desktop or select the program from the Rosslare folder in the Start menu The Login dialog is displayed Figure 11 AS B01 Login Dialog 2 Enter a password The default password is admin The AS B01 software Main window is displayed Figure 12 AS B01 Main Window ...

Страница 18: ...menu area used for general operations such as setting global options on the Desktop Programmer getting version information and closing the software Configuration Tab area the main working area All card and swipe configuration parameters are entered and displayed Note Descriptions for fields requiring parameters under all the tabs are described in Appendix A There are two programming tabs Sector re...

Страница 19: ...uction messages for example during fingerprints enrollment Status information area indicates connection status with the CP R25 Desktop Programmer hardware 4 3 Indication LED s The following table describes LED behavior on the CP R25 Programmer see Figure 2 CP R25 Description General Event Swipe Card Reader LED Fingerprint Reader LED Buzzer Fingerprint Directional Indication LED Power on One red LE...

Страница 20: ... on Fingerprint Scanning Event Swipe Card Reader LED Fingerprint Reader LED Buzzer Fingerprint Directional Indication LED Waiting for fingerprint Off Green flashing Off Rolling LEDs in circular mode to indicate finger swipe Read fingerprint success Off Green on for 3 sec 3 High tone beeps Rolling LEDs in circular mode to indicate finger swipe Read fingerprint fail Off Red on for 3 sec Short buzz T...

Страница 21: ...sub areas in the Configuration Tab area General Reader area this area is the same for all configuration functions Reader Specific Configurations area this area has two different versions depending on whether it is a Sector Reader configuration or a Swipe Reader configuration Operations area this area varies according to the configuration function being performed The configuration function is selec...

Страница 22: ...ntify the user cards or tags User Card this is used to enable access by presenting the card or tag to the reader With readers requiring fingerprint identification the same card or tag is used in conjunction with swiping of the fingertip 5 1 Programming Configuration Cards Configuration Cards are used for configuring specific Rosslare MIFARE and Fingerprint reader s operation modes Holding the Conf...

Страница 23: ...6360 and many more To Prepare Sector Reader Configuration Card 1 Select Sector Reader tab 2 Select the applicable Operation Mode either Sector or Card Serial Number CSN For Sector operation mode define the ID Location using the Sector Number Block Number and Byte Number fields 3 Ensure that the Operations is set to Program Card 4 From the Operation Type dropdown menu select Program configuration c...

Страница 24: ...IFARE card On completion a message is displayed in the Message Log area to verify that the programming succeeded If the programming is a failure there is a short buzz and the swipe Card Reader LEDs lights red for three seconds 5 3 Fingerprint Swipe Reader Configuration Cards The Fingerprint Swipe reader configuration card allows the creation of a configuration card used to configure the various Fi...

Страница 25: ...g this secret key to unauthorized personnel The KeyA value is entered as a 12 hexadecimal digit with the format FFFFFFFFFFFF 11 Place a blank MIFARE card or a card previously configured as a Configuration Card on the CP R25 Desktop Programmer antenna area 12 Click Start to begin programming the MIFARE card On completion a message is displayed in the Message Log area to verify that the programming ...

Страница 26: ...previously configured MIFARE User Card Once the card is configured the Card ID and the KeyA value can be modified of if required completely wiped from the card There is also an option to configure the Card ID KeyA programmer key as well as do the fingerprint enrollment on a previously configured MIFARE User Card in one operation 5 5 Programming a Sector Read User Card The first stage of preparing ...

Страница 27: ... hexadecimal digit The default KeyA is FFFFFFFFFFFF 8 Type the User Card ID or scroll using the Up and Down arrows The value can be between 0 and 16777215 9 Place a MIFARE card on the CP R25 Desktop Programmer antenna area 10 Click Start to begin programming the MIFARE card On completion a message is displayed in the Message Log area to verify that the programming succeeded If the programming is a...

Страница 28: ...eyA to be authenticated by the reader as the unique KeyA for the organization or site Type the same value in the New KeyA and the Confirm New KeyA fields enter the Current KeyA of the card being programmed Note The KeyA number is hidden by characters so write down the new key and keep it in a safe place to avoid exposing this secret key to unauthorized personnel The KeyA value is entered as a 12 h...

Страница 29: ...system settings see Global Options Error Reference source not found Error Bookmark not defined the system will alert if the card being programmed is not empty The Card not empty do you want to overwrite it prompt message is displayed Choose to either Continue or Cancel A long buzzer beep indicates failure On successful completion of all three reads and card programming 3 short beeps are generated ...

Страница 30: ...de or the Card Serial Number CSN Operation Mode All options available for the Card Serial Number CSN Operation Mode are also available for the Sector Operation Mode The Sector Operation Mode has additional utilities specific to the Sector type card 6 2 Reading a Configuration Card This function can be used to confirm the card configuration when performing other functions saving time and enhancing ...

Страница 31: ...he applicable transmission format 5 Select the Card Type either Mifare 1 K or Mifare 4 K 6 From the Operation Type field drop down menu select Read ID from User Card The KeyA and MIFARE User Card ID fields are displayed 7 For security reasons type the KeyA for the card being read 8 Place the MIFARE User Card on the CP R25 Desktop Programmer antenna area 9 Click Start to display the card ID in the ...

Страница 32: ... Card on the CP R25 Desktop Programmer antenna area 11 Click Start to begin programming procedure 6 5 Changing the User Card KeyA in a specific Sector Used to change the KeyA value in a specific sector of the User Card without changing the card template or User Card ID To Change the KeyA in a specific sector 1 Select either the Sector Reader tab or the Swipe Reader tab 2 In the Operations area sel...

Страница 33: ...ld drop down menu select Change User Card KeyA and erase data all sectors The KeyA fields are displayed 5 Type the same value in the New KeyA and the Confirm New KeyA fields enter the Current KeyA of the card being programmed 6 Place the MIFARE User Card on the CP R25 Desktop Programmer antenna area 7 Click Start to start the formatting procedure Note This operation may take a long time to process...

Страница 34: ...for the card being read 8 Place the MIFARE User Card on the CP R25 Desktop Programmer antenna area 9 Click Start to erase the data from the specific sector within the card 6 8 Read Serial number and Card Type Each MIFARE card has a Unique Serial Number UID To read a MIFARE User Card Serial Number and Type 1 Select either the Sector Reader tab or the Swipe Reader tab 2 In the Operations area select...

Страница 35: ...d 4 Select the number of fingers to enroll 5 Check the Verify after enrollment checkbox to verify the enrolled fingerprints if required This usually not required as the CP R25 Desktop Programmer has an automatic internal verification on enrollment 6 For security reasons the KeyA for the card needs to be written to keep the KeyA value type the same value in the New KeyA the Confirm New KeyA and the...

Страница 36: ...ger utilities 3 From the Operation Type drop down menu select Verify live fingerprint 4 Select the number of fingers that were enrolled for verification 5 For security reasons the KeyA for the card needs to be written to keep the KeyA value type the same value in the New KeyA the Confirm New KeyA and the Current KeyA fields 6 Place the card on the CP R25 Desktop Programmer antenna area 7 Click Sta...

Страница 37: ...enu click Options Æ Change Password The Change Password window is displayed Figure 16 AS B01 Change Password 2 Complete the fields as required To change the password it is necessary to first enter the current password and then enter the new password twice for confirmation Passwords are case sensitive For higher security make sure that the passwords you choose is more than 4 letters long Mixing let...

Страница 38: ... write information onto a card with Data already stored on it If disabled the system will overwrite information automatically without warning the user To enable Card Overwrite warning 1 In the File menu click Options Æ Card overwrite The Overwrite pop up window appears Figure 17 Enable Card Overwrite Pop up Window 2 Check the checkbox to enable warning 3 Click OK ...

Страница 39: ...the ground This may cause electromechanical failure When required update the firmware To update the CP R25 Desktop Programmer firmware 1 In the File menu click Options Æ Firmware Programming The Desktop Reader Firmware Programming window is displayed Figure 18 AS B01 Desktop Reader Firmware Programming 2 The default firmware location is displayed in the bin file location field To select another lo...

Страница 40: ...nnect the USB Cable Wait until the indicator at the left bottom side of the screen displays Connected The installation automatically begins On completion the Firmware Update Complete screen is displayed Figure 20 Firmware Update Complete The Desktop firmware is now updated Two more messages should immediately follow in the Message window MIFARE Programming Reader Disconnected and MIFARE Programmin...

Страница 41: ...Maintenance CP R25 Hardware Software Manual Page 40 ...

Страница 42: ...ze and memory location on the card There are two options MIFARE 1K memory The 1024 x 8 bit EEPROM memory is organized in 16 sectors with 4 blocks of 16 bytes each In the erased state the EEPROM cells are read as a logical 0 in the written state as a logical 1 MIFARE 4K memory The 4096 x 8 bit EEPROM memory is organized in 32 sectors with 4 blocks and 8 sectors with 16 blocks Each block contains 16...

Страница 43: ...empts Defines the number times a user can present a wrong card or swipe an unverified fingerprint before the reader locks the door for a predefined period of time Lockout Duration Defines how long a card is locked out of the system after too many invalid attempts at swiping the card through the reader or fingerprint scanned due to some inconsistencies with the configured card being used New Passwo...

Страница 44: ...ecting Sector mode including the Reader KeyA and the ID Location fields Transmit Format Wiegand protocol is a secure transmission format where access control is required The different bit configuration is used to define different security options specified by the company security officer MIFARE User Card ID Unique ID assigned to the card This ID number is obtained from the company security officer...

Страница 45: ...card is read from manufacture block Data blocks All sectors contain 3 blocks of 16 bytes for storing data Sector 0 contains only two data blocks and the read only manufacturer block The data blocks can be configured by the access bits as read write blocks for e g contactless access control or Value blocks for e g electronic purse applications not supported by AS B01 An authentication command has t...

Страница 46: ...itional MIFARE Card Memory Map Information CP R25 Hardware Software Manual Page 45 Figure 21 MIFARE 1K Memory Diagram For further details about MIFARE cards refer to the NXP Semiconductor MIFARE datasheet ...

Страница 47: ...he following sample form can be used Employee Security Card Configuration Field Configuration Employee Name Employee ID Employee Company ID Employee Dept Card Serial Number if applicable Reader KeyA Transmit Format Card Type 1K or 4K ID Location Sector Number ID Location Block Number ID Location Byte Number MIFARE User Card ID Number of Fingerprints 1 or 2 LED Control Buzzer Control Lockout Attemp...

Страница 48: ...rms of this warranty Unless otherwise requested by ROSSLARE ENTERPRISES LTD AND OR SUBSIDIARIES representative return of the failed product s is not immediately required If ROSSLARE has not contacted the Customer within a sixty 60 day holding period following the delivery of the warranty claim Customer will not be required to return the failed product s All returned Product s as may be requested a...

Страница 49: ... the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim ROSSLARE does not warrant the installation maintenance or service of the Product Service life of the product is dependent upon the care it receives and the conditions under which it has to operate In no event shall Rosslare be ...

Страница 50: ...ed States and Canada 1600 Hart Court Suite 103 Southlake TX USA 76092 Toll Free 1 866 632 1101 Local 1 817 305 0006 Fax 1 817 305 0069 E mail support na rosslaresecurity com Europe Global Technical Support Training Center HaMelecha 22 Rosh HaAyin Israel 48091 Tel 972 3 938 6838 Fax 972 3 938 6830 E mail support eu rosslaresecurity com South America Pringles 868 1640 Martinez Buenos Aires Argentina...

Страница 51: ......

Страница 52: ...0706 0960349 00 www rosslaresecurity com ...

Отзывы: