Fingerprint Enrollment
24
AYC-B7661 Installation Manual
If valid, the unit emits three short beeps and the LEDs blink
green. The user’s fingerprint template is then stored in the
defined record within the unit.
If an enrollment error occurs, the unit emits an error tone and
the LEDs turn red for about one second.
To delete enrolled users (fingerprint and user card) in 1:1
mode:
1.
When the reader is in Standby mode, present the Delete card to
the reader.
Both LEDs flash orange.
2.
Present the record number (+10 and +1) cards the number of
times required to reach the desired record number.
Each time a card is presented the reader emits one beep.
For example, to enroll a fingerprint to record number 32
present the +10 card three times followed by the +1 card twice.
3.
Present the Delete card.
If valid, the unit emits three short beeps and the LEDs blink green.
The users do not need to place their finger on the unit’s sensor.
If an error occurs, the unit emits an error tone and the LEDs turn
red for about one second.
To add a user card to an ex isting fingerprint record:
1.
When the reader is in Standby mode, present the Add card
configuration card to the reader.
Both LEDs flash orange.
2.
Present the record number (+10 and +1) cards the number of
times required to reach the desired record number.
Each time a card is presented the reader emits one beep.
For example, to enroll a fingerprint to record number 32
present the +10 card three times followed by the +1 card twice.