Reader/Controller Configuration
AYC-B7661 Installation Manual
19
4.
Reader/Controller Configuration
4.1
Configuring the Unit
To provide the highest level of security, the reader is programmed to
validate only MIFARE
cards whose settings correspond to the Master
card that is used to bring the reader into Configuration mode, where
the following settings can be configured:
Card transfer format
MIFARE card Key A value
LED and buzzer control enable
Lock-out settings
Transmission of Card Serial Number (CSN) or card ID from
dedicated sector
In addition, it is possible to browse between 1:1 and 1:N modes.
The Master and Configuration cards are configured using the
Desktop Programmer (CP-R26). Refer to the
CP-R26 Hardware
and AS-B01 Software Manual
for more details.
4.2
Configuration Procedure
The reader does not work until it is configured upon initial use. It is
recommended to configure the reader one time only, following
installation and its initial use. However, if needed, configuring the
reader can be done anytime using the same procedure described
below.
To configure the unit:
1.
Present the Master card.
A short beep is generated and the two LEDs begin to blink in
orange, as the reader goes into Configuration mode.
2.
Within 30 seconds (while the reader is still in Configuration
mode), present a valid Configuration card to the reader.