82 • DashBoard Interface Overview
RCP-ME User Guide (v4.0)
Configuration Options
Newly assigned IP addresses and netmasks are checked for valid values before being applied to an RCP-ME. If
the new values are invalid they will be discarded silently. Only a refresh of the RCP-ME Connection Editor will
show that the values were not set.
The bottom half of the RCP-ME Connection Editor is organized into three areas: Network Settings, Servers to
Connect to, and Connections. A toolbar at the bottom of the RCP-ME Connection Editor provides buttons for
updating the panel.
Network Settings Area
summarizes the options for specifying the network settings for the RCP-ME.
Servers to Connect to Area
summarizes the options for configuring communications between the RCP-ME and a server.
Details
<text>
Assigned by the user to give an RCP-ME specific
details. For example, a physical location or a brief
description of its use.
This field has a maximum of 16 characters and is
used for description and identification only.
MAC Address
(read-only)
#
The Media Access Control address (MAC address)
is the unique hardware address for the RCP-ME on
a network. This parameter is not user configurable
Name
<text>
This field can be assigned by the user to uniquely
name an RCP-ME.
This field has a maximum of 16 characters and is
used for description and identification only. The
DashBoard tree view uses the text in this field as
the device tree name.
Group
#
A group number can be assigned by the user to
organize devices into groups. For example, users
can assign separate group numbers for devices in
different physical areas.
This field has a maximum of 10 characters and by
default is blank.
Table 16.2 Network Settings Area
Item
Parameters
Description
IP Address
#.#.#.#
Enter or edit the IP address of the device
Netmask
#.#.#.#
Enter or edit the IP netmask of the device
Gateway
#.#.#.#
Enter or edit the IP gateway of the device
TCP Port
#
Enter or select the Transmission Control Protocol
port number used for network communication. By
default, the TCP Port is 5000, and any client
devices/apps should be setup with the same port
number
Table 16.1 Device Details Area
Item
Parameters
Description
Содержание Ultricore RCP-ME
Страница 1: ...RCP ME User Guide...
Страница 6: ......
Страница 10: ...iv Contents RCP ME User Guide v4 0...
Страница 14: ...14 Introduction RCP ME User Guide v4 0...
Страница 28: ...28 Getting Started RCP ME User Guide v4 0...
Страница 54: ...54 Macros RCP ME User Guide v4 0...
Страница 56: ...56 Salvos RCP ME User Guide v4 0...
Страница 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Страница 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Страница 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Страница 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Страница 80: ...80 Monitoring RCP ME User Guide v4 0...
Страница 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Страница 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...
Страница 98: ...98 Glossary RCP ME User Guide v4 0...