RCP-ME User Guide (v4.0)
Machine Control • 65
Machine Control
When configuring the RCP-ME, you have the option to enable Machine Control, and to add a Machine Control
button to the panel.
What is Machine Control?
Typically, the ports on a data router (such as the NK-M series routers) are bi-directional where there is both a
transmit (input to output) and reciprocal receive connection that is made for each port. For example, a switch from
port 1 to port 2 involves a forward path (from port 1 input to port 2 output) and the reciprocal connection from (port
2 input to port 1 output).
In some cases however, there is a need to connect on the port’s input to several ports’ output (e.g. one device
commanding many target devices) without making the reciprocal connection. This allows the commanding device
to just broadcast commands and not receive from the many devices it communicates with.
Setting Up Machine Control
If your routing switcher system uses a machine control routing switcher to provide reciprocal switching of RS-422
signals, your RCP-ME must be set up to handle these switches. Machine control must be enabled in the RCP-ME
and the router level used for machine control must match that set in the machine control routing switcher.
To set up machine control
1. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
2. Select the
Configuration
tab.
3. In the
Configuration
section, select the
Machine Control Enabled
check box.
4. Use the
Machine Control Level
box to enter or select the machine control level to match the level that the
machine control routing switcher has been assigned.
5. Send the current configuration file to the device (see “
To send the current configuration to a panel
page 74).
Assigning a Machine Control Button
If your master device controls multiple slave devices, you need a machine control button to temporarily disable
reciprocal switching until the last slave device is routed.
To assign a machine control button
1. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
2. On the simulated RCP-ME, select the button that you want to use for machine control.
The
Button
configuration box opens.
3. In the
Button
list, select
Function Key
.
4. Use the
Value
list to select
MC Key
.
5. Close the
Button
configuration box.
The simulated RCP-ME in DashBoard shows
MC KEY
on the selected button.
6. Send the current configuration file to the device (see “
To send the current configuration to a panel
page 74).
Содержание Ultricore RCP-ME
Страница 1: ...RCP ME User Guide...
Страница 6: ......
Страница 10: ...iv Contents RCP ME User Guide v4 0...
Страница 14: ...14 Introduction RCP ME User Guide v4 0...
Страница 28: ...28 Getting Started RCP ME User Guide v4 0...
Страница 54: ...54 Macros RCP ME User Guide v4 0...
Страница 56: ...56 Salvos RCP ME User Guide v4 0...
Страница 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Страница 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Страница 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Страница 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Страница 80: ...80 Monitoring RCP ME User Guide v4 0...
Страница 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Страница 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...
Страница 98: ...98 Glossary RCP ME User Guide v4 0...