RCP-ME User Guide (v4.0)
Linking Remote Control Panels • 67
Linking Remote Control Panels
If your routing switcher system is extensive, control of the entire system may not be possible through just one
remote control panel. If this is the case, additional remote control panels may be added. You can choose to operate
the remote control panels individually, or you can link the remote control panels together so they operate as one
larger remote control panel.
You may link up to 10 remote control panels together.
Before You Begin
When multiple remote control panels are linked, the
Address
field must be the same for all linked remote control
panels, and the
Panel Link Address
field must be different for each remote control panel.
You may link RCP-ME, RCP-QE, RCP-NKM, and RCP-NKQ remote control panels together. You cannot link the
RCP-NK1 with an RCP-ME, RCP-QE, RCP-NKM, or RCP-NKQ.
The
Panel Address
and
Panel Link Address
must be different within each remote control panel. For example, if
you have three RCP-ME panels but only want to link two panels, you would assign the Panel Address and Panel
Link Addresses as outlined in Table 12.1. In this example, the first and second panels are linked to form one logical
remote control panel.
Configure a Link Between Multiple Remote Control Panels
RCP-ME panel linking requires a connection to either an NK-NET, an Ultrix router, or an Ultricore Central
Controller. The NK-IPS does not support panel linking.
To link remote control panels together
1. Open the RCP-ME Panel Config interface (see “
To open the RCP-ME Panel Config interface
2. In the
Address
field of the
Device Details
area, enter the common address (between 2 and 255) that you want
all the linked remote control panels to use.
3. Select the
Configuration
tab.
4. In the
Panel Link Address
field of the
Panel Link
area, enter the individual address (between 1 and 254) that
you want this specific remote control panel to use. By default, the
Panel Link Address
of a remote control
panel is set to zero (0).
If a panel has a
Panel Link Address
of
0
, it cannot have the same address of another panel or other NK series
device. If it does, the results will be unpredictable.
5. Send the current configuration file to the device (see “
To send the current configuration to a panel
page 74).
6. Repeat this process for all the remote control panels that you want to link together.
Table 12.1 Example of Linked Panel Addresses
First
RCP-ME
Second
RCP-ME
Third
RCP-ME
Setup
Linked
Unlinked
Address
100
100
120
Panel Link Address
1
2
0
Содержание Ultricore RCP-ME
Страница 1: ...RCP ME User Guide...
Страница 6: ......
Страница 10: ...iv Contents RCP ME User Guide v4 0...
Страница 14: ...14 Introduction RCP ME User Guide v4 0...
Страница 28: ...28 Getting Started RCP ME User Guide v4 0...
Страница 54: ...54 Macros RCP ME User Guide v4 0...
Страница 56: ...56 Salvos RCP ME User Guide v4 0...
Страница 60: ...60 Category Index Mode RCP ME User Guide v4 0...
Страница 70: ...70 Linking Remote Control Panels RCP ME User Guide v4 0...
Страница 72: ...72 Cutbus Mode RCP ME User Guide v4 0...
Страница 76: ...76 Managing Panel Configurations RCP ME User Guide v4 0...
Страница 80: ...80 Monitoring RCP ME User Guide v4 0...
Страница 94: ...94 DashBoard Interface Overview RCP ME User Guide v4 0...
Страница 96: ...17 96 RCP ME Hexadecimal to Router Level Conversion RCP ME User Guide v4 0...
Страница 98: ...98 Glossary RCP ME User Guide v4 0...