Configuring the Encoder for Setup Mode
Whenever the TES9’s power is turned on, it begins operation using parameters stored in its
configuration memory. In order to change these operating parameters via
Port A
or the modem,
the TES9 must be placed in setup mode. All data sources should stop sending data to the encoder
before running TES9Set.
To select Setup mode
1.
Ensure that the TES9 has completed its power-up sequence and is operational.
2.
Press and hold the
LOAD
switch located on the TES9's rear panel for at least two
seconds. Refer to the
TES9 Hardware Manual
for switch location.
3.
When the
STATUS 1
LED begins alternating between green and yellow, the TES9 is
ready to be configured, and waiting for TES9Set to communicate with it using one of its
ports (
Port A
, modem or LAN).
4.
The TES9 will leave Setup mode when you exit from TES9Set or you turn the TES9's
power off and on again.
To use setup via the LAN
1.
You need to initially set the encoder's IP address through
Port A
or the modem, using
the above procedure.
2.
After this initial setup, the TES9's configuration can be changed via the LAN connection
at any time, without pressing the
LOAD
switch to select
Setup
mode.