![Ross openGear GPI-8941 Series Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/ross/opengear-gpi-8941-series/opengear-gpi-8941-series_user-manual_1488993052.webp)
52 • Configuring the GPI Outputs
GPI-8941 User Guide (v9.0)
4. Use the
Type
menu to specify whether the circuit is Wet or Dry. Choose from the following:
•
Contact Closure
— When the output is on the output pins are connected together by a pair of relay contacts.
When the output is off the output pins are not connected. The output pins are isolated from the card circuit.
(Dry)
•
Voltage Source
— When the output is on the + output pin is connected to an in5VDC power supply.
When the output is off the + output pin is not connected. The other output pin is always connected to ground.
(Wet)
5. Use the
Polarity
menu for level-triggered GPI outputs to set whether triggers are
Normal
(Active High) or
Inverted
(Active Low).
6. Use the
Power Up State
menu to set the state of the GPI Output after a card power cycle.
7. Use the
Pulse Width
menu to specify the number of milliseconds (mS) a pulse will be sent.
8. Use the
Output
menu to specify the behavior of the GPI Output. Choose from the following:
•
Pulse
— select this option to generate a pulse when triggered. The pulse must be completely finished before
it can be triggered again.
•
Maintained
— select if the GPI output is level triggered where ON is High and OFF is Low. The Pulse
Width setting is ignored.
•
Retrig. Pulse
— the card will generate a pulse when triggered. If the card receives anther trigger before the
end of the pulse, the pulse will be extended by the Pulse Width time.
9. Use the
Timing
menu to specify whether to use the Timing Window options specified in the
Config
tab.
Choose from the following:
•
Immediate
— the
Timing Window
settings are ignored. Commands are executed without pauses.
•
Synced
— the
Timing Window
settings are applied. Commands are executed during the Timing Window as
determined by the Start and Stop lines for the reference signal in use.
If the GPI output is set to Synced and if the reference is not configured or invalid, the timing is immediate.
Содержание openGear GPI-8941 Series
Страница 1: ...GPI 8941 Series User Guide...
Страница 6: ......
Страница 10: ...iv Contents GPI 8941 Series User Guide v9 0...
Страница 16: ...16 Before You Begin GPI 8941 Series User Guide v9 0...
Страница 20: ...20 Hardware Overview GPI 8941 Series User Guide v9 0...
Страница 30: ...30 GPIO Cabling GPI 8941 Series User Guide v9 0...
Страница 32: ...32 Reference Cabling GPI 8941 Series User Guide v9 0...
Страница 56: ...56 Software Upgrades GPI 8941 User Guide v9 0...
Страница 70: ...70 DashBoard Menus GPI 8941 Series User Guide v9 0...
Страница 72: ...72 Technical Specifications GPI 8941 Series User Guide v9 0...
Страница 86: ...86 RossTalk Protocol GPI 8941 User Guide v9 0...
Страница 88: ...88 Software Licenses GPI 8941 User Guide v9 0...
Страница 92: ...92 Glossary GPI 8941 Series User Guide v9 0...