![Ross Abekas Tria+ UHD Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/ross/abekas-tria-uhd/abekas-tria-uhd_user-manual_1488988061.webp)
8.
In the
AMP Protocol Configuration
area at the bottom of the window, select specific configurations for the
protocol you are using.
• Select
Disable field timecode reporting
to force the server to report timecode only once every video frame.
If this option is not selected, the server reports timecode every field.
• Select
Allow overlapped commands
to allow the server to accept overlapping commands.
• Select
Allow playlist control
to allow control over the playlist.
• Select the
Protocol ID
that you want to use (
Abekas 6000
,
Sony BVW-75
, or
Generic DDR
).
9.
Click on the
Ch-
X
:
list and select the room that you want to assign to the channel.
10.
Click
Restart Tria
. A confirmation dialog box is displayed.
11.
Click
Restart Tria
to restart the server application and services with the new setting.
12.
Click
OK
when the restart has completed to dismiss the window.
DashBoard
The DashBoard control system allows remote access to multiple pieces of Ross Video equipment, including openGear
®
cards, Carbonite production switchers, Ross video servers, and Ross cameras. Download and install the latest version of
www.rossvideo.com/support/software-downloads/
Review the documentation that comes with DashBoard for information on installing and launching DashBoard.
To control Tria+ UHD from DashBoard you must create a custom panel in DashBoard using PanelBuilder to send
VDCP or Tria+ UHD Ethernet API commands to the server.
Note:
DashBoard can only display video previews for channel transports if DashBoard is running on the same Tria+ UHD server.
Clip ID Support
Devices using the VDCP or Odetics protocol can use the 8-character clip ID assigned to a clip. By default, the server
does not assign a clip ID to the clip when it is recorded. If there is no clip ID, the first 8 characters of the clip name are
used instead.
Sony
®
MVS Series Switcher
Use the following information to set up your Sony
®
MVS series switcher to control the server as either a
Recorder
or
Player
device.
Table 3: VDCP RS422 Protocol Constants
No.
Item
Setting
1
Video Port
(1-N)*
2
Maximum Open Delay
10
3
Maximum Cueup Delay
0
4
Play After Cueup Delay
0
5
Stop Delay
2
6
Still Delay
6
7
Continue Delay
0
8
Idle Delay
2
* Set this value to the MVS virtual RS422 Port # that is connected to the server.
Tria+ UHD User Manual — Remote Control Support •