Reference Manual
00809-0100-4030, Rev DA
June 2007
Rosemount 2120
1-2
Switch Overview
The Rosemount 2120 is a liquid point level switch based on the vibrating short fork
technology making it suitable for virtually all liquid applications. Complete range of process
connections, wide choice of housing and wetted parts materials, four different switching
functions, extended fork lengths, hazardous area and overfill approvals makes it
configurable to almost all requirements.
Short Fork Technology
The natural frequency (~1300Hz) of the fork is chosen to avoid interference from plant
vibration which may cause false switching. This also gives short fork length for minimal
intrusion into vessel and pipe. Using Short Fork Technology, the Rosemount 2120 is
designed for use in virtually all liquid applications. Extensive research has maximized the
operational effectiveness of the fork design making it suitable for almost all liquids, including
coating liquids (avoid bridging of forks), aerated liquids, and slurries.
Rosemount 2120 Application and Mounting Examples
For most liquids including coating and aerated liquids and slurries, the function is virtually
unaffected by flow, turbulence, bubbles, foam, vibration, solid particles, build-up (avoid
bridging of forks) or properties of the liquid. For use in Hazardous (IS or Exd) or safe area
and process temperatures up to 302°F (150°C).
Mount in any position in the tank or pipe. Mounting is by a wide range of threaded,
flanged, or hygienic connection.
Any substitution of non-recognized parts may jeopardize safety and is under no
circumstances allowed.
‘Fast drip’
fork design
Mode switch,
adjustable time
delay
Visible heartbeat
LED
Wetted material in SST, Hastelloy or
Halar/PFA coating
Short fork length or
extensions up to 118-in. (3 m)
IP66/67 or NEMA4X
housings in plastic,
aluminum or 316 SST
Two cable/ conduit
entries
Direct Load, Relay PLC/PNP,
or IS NAMUR electronics
Threaded, Flanged, or
Hygienic Connections
Magnetic test
point
2
1
2
1
0
/21
20 top
of
f.ti
f
Содержание 2120
Страница 2: ......
Страница 4: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 ...
Страница 8: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 TOC 4 ...
Страница 68: ...Reference Manual 00809 0100 4030 Rev DA June 2007 Rosemount 2120 B 20 ...
Страница 69: ......
Страница 70: ......
Страница 71: ......