background image

Galaxy A16F-R2422 Installation and Hardware Reference Manual

  

 
 

 Hardware Installation 

2-6 

2.6.2 Uninstalled Components 

You must install the following components: 

 

Drive trays with hard drives pre-installed 

 
 

2.7  Hard Drive Installation 

2.7.1 Hard Drive Installation Prerequisites 

Hard drives for the Galaxy subsystem must be purchased separately. When 

purchasing the hard drives, the following factors should be considered: 

Capacity (MB/GB): 

Use drives with the same capacity.  RAID arrays use a 

“least-common-denominator” approach. The maximum capacity of each 

drive used in the array is the maximum capacity of the smallest drive. 

Choose big drives with the same storage capacity. 

Profile: 

The drive trays and bays of the system are designed for 3.5-inch 

wide x 1-inch-high hard drives. It is highly recommended that you do not try 

to use drives of any other size. 

Drive type:

 The A16F-R2422 described in this manual can use SATA-II or 

SATA-I hard drives. Please ensure that you purchase the correct hard drives. 

MUX kit:

 All drive trays come with preinstalled MUX kits to facilitate the 

transaction of SATA-II and SATA-I hard drives data to Fibre host channels. 

 

CAUTION! 

The hard drives and drive trays should only be installed into the 

subsystem after the subsystem has been mounted into a rack cabinet. If 

the hard drives are installed first, the subsystem will be too heavy to lift 

and the possible impact during installation may damage your drives. 

 

 

WARNING!

 

1.

 

Handle hard drives with extreme care. Hard drives are very 

delicate.  Dropping a drive onto a hard surface (even from a short 

distance) and hitting or touching the circuits on the drives with your 

tools may cause damage to the drives. 

2.

 

Observe all ESD prevention methods when installing drives. 

3.

 

Only use screws supplied with the drive canisters. Longer screws 

may damage the drive. 

Содержание Galaxy A16F-R2422

Страница 1: ...Galaxy Raid Model A16F R2422 FC 4G to SATA II RAID Subsystem Redundant Controller Installation and Hardware Reference Manual Version 0906 Version 1 0 08 2005...

Страница 2: ...tion and Hardware Reference Manual ii Contact Information Americas Rorke Data Inc 9700 West 76th St Eden Prairie MN 55344 USA Tel 1 800 328 8147 Fax 1 952 829 0988 sales rorke com techsupport rorke co...

Страница 3: ...of and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose Furthermore Rorke Data reserves the right to revise this publication and to make changes f...

Страница 4: ...ent is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmf...

Страница 5: ...rd to establishing a satisfactory level of safety for persons using the device and for the area surrounding the apparatus This standard covers only safety aspects of the above apparatus it does not co...

Страница 6: ...1 11 1 3 GALAXY MONITORING 1 12 1 3 1 I2C bus 1 12 1 3 2 LED Indicators 1 12 1 3 3 Firmware FW and RAIDWatch GUI 1 13 1 3 4 Audible Alarms 1 13 1 4 HOT SWAPPABLE COMPONENTS 1 13 1 4 1 Hot swap Capabi...

Страница 7: ...ault Threshold Values 3 10 3 3 2 Failed Devices 3 11 3 4 I2C MONITORING 3 11 CHAPTER 4 SUBSYSTEM CONNECTION AND OPERATION 4 1 FC HOST CONNECTION PREREQUISITES 4 1 4 1 1 Choosing the Fibre Cables 4 1 4...

Страница 8: ...5 14 5 7 1 Hard Drive Maintenance Overview 5 14 5 7 2 Replacing a Hard Drive 5 15 APPENDIX A UNINTERRUPTIBLE POWER SUPPLY A 1 UNINTERRUPTIBLE POWER SUPPLY OVERVIEW A 1 A 2 COMPATIBLE UPS SUPPLIES A 1...

Страница 9: ...modules using the retention screws eject levers and the metal frames face plates Avoid touching PCB boards and connector pins To comply with safety emission or thermal requirements none of the covers...

Страница 10: ...details about the hardware installation process Briefly describes how to monitor the subsystem Describes how to maintain the subsystem This manual does not Describe components that are not user servic...

Страница 11: ...cts They can be read in any order Each statement is preceded by a round black dot Numbered Lists Numbered lists are used to describe sequential steps you should follow in order Important information t...

Страница 12: ...t software or firmware updates Problems that occur during the updating process may cause unrecoverable errors and system down time Always consult technical personnel before proceeding with any firmwar...

Страница 13: ...es failure at the same time when its configuration is RAID level 6 This generates a higher redundant level of data availability On this system the RAID level 6 and 60 are both ready for end users Plea...

Страница 14: ...contents against the included Unpacking Checklist If any modules are missing please contact your subsystem vendor immediately 1 1 2 Enclosure Chassis 1 1 2 1 Chassis Overview The A16F R2422 RAID stora...

Страница 15: ...he two 2 handles on the front of the subsystem enable you to easily insert extract the chassis into from a rack or cabinet The LCD panel on the left handle provides an easy way for you to monitor and...

Страница 16: ...rear panel and is reserved for dual RAID controller modules two 2 standard BBUs two 2 host connection modules two 2 power supply units PSUs two 2 cooling modules and an enclosure configuration card T...

Страница 17: ...rn the system on and off See Section 1 2 8 Cooling modules The redundant cooling modules provide ventilation to reduce the temperature within the subsystem See Section 1 2 9 Enclosure configuration ca...

Страница 18: ...ller or different logical drive This will enable easier identification in a topology with numerous arrays 1 2 2 Drive Trays Figure 1 7 Drive Tray Front View PN GAL 9273A2DT2S1S The A16F R2422 subsyste...

Страница 19: ...xteen 16 pre installed SATA II to SATA multiplexer MUX kits one in each drive tray These MUX kits facilitate the installation of separately purchased SATA II or SATA I drives When installing the drive...

Страница 20: ...omes with two 2 pre set FC 4G host channels CH0 and CH1 The subsystem connects to the external FC 4G host computer s via eight 8 FC connectors which are located on the host connection modules These FC...

Страница 21: ...nues the monitoring or configuration service Shielded cables must be used to protect against emissions Connect the other end of the Ethernet cable to a LAN hub port of the local network COM ports Each...

Страница 22: ...is being changed the controller module must be removed from the subsystem chassis 1 2 7 Battery Backup Units BBUs Figure 1 11 BBU PN GAL 9273CBTC Two 2 standard Li ION battery backup units BBUs see F...

Страница 23: ...12 each PSU comes with a single power socket for power cord plug in and a power switch on the right to turn the subsystem on and off Two 2 embedded cooling fans provide sufficient airflow to keep the...

Страница 24: ...le operate with two rotation speeds Under normal operating conditions the cooling fans run at the low speed which is sufficient for maintaining efficient airflow across components Under the following...

Страница 25: ...cations are listed in Appendix B 1 2 10 Enclosure Configuration Card Figure 1 14 DIP Switch A DIP switch on the enclosure configuration card see Figure 1 14 is conveniently located on the left side of...

Страница 26: ...The bypass circuits ensure loop integrity and allow you to configure redundant paths to the host computers For configurations involving multi path multi host computers and cascading A16F R2422 be sur...

Страница 27: ...connection of the existing host interface or Ethernet link to the array s LAN port 1 3 4 Audible Alarms The A16F R2422 subsystem comes with audible alarms that are triggered when certain active compon...

Страница 28: ...es in dual active mode Host connection modules PSUs Cooling modules BBUs Hard drives NOTE Instructions on how to replace these hot swappable components are given in Chapter 5 1 4 3 Normalized Airflow...

Страница 29: ...2 Installation Prerequisites 1 Static free installation environment The A16F R2422 subsystem must be installed in a static free environment to minimize the possibility of electrostatic discharge ESD...

Страница 30: ...odule slot open will greatly affect the airflow efficiency within the enclosure and will consequently lead to system overheating Keep a faulty module in place until you have a replacement unit and you...

Страница 31: ...in your body by wearing an anti static wristband Avoid carpets plastic vinyl and Styrofoam in your work area Handle all components by holding their edges or metal frames Avoid touching the exposed cir...

Страница 32: ...r cords that came with the subsystem to connect the subsystem to the main power source Use the self purchased Fibre cable to connect a host port to the host computer or an external device 6 Power up O...

Страница 33: ...level One 1 box contains the enclosure chassis with all the pre installed components The other two 2 boxes contain the power cords and accessory items Accessory items include an audio jack to DB9 Y ca...

Страница 34: ...ot try to use drives of any other size Drive type The A16F R2422 described in this manual can use SATA II or SATA I hard drives Please ensure that you purchase the correct hard drives MUX kit All driv...

Страница 35: ...he drive at an angle and inserting it into the drive tray See Figure 2 2 Figure 2 2 Installing a SATA Hard Drive Step 3 Connect the drive to the MUX kit by sliding it towards the rear of the drive tra...

Страница 36: ...the unlocked position i e the groove on its face is in a horizontal orientation as shown in Figure 2 5 If the groove is in a vertical position then the key lock is locked and the front flap on the dri...

Страница 37: ...n the MUX kit at the back of the drive tray is firmly connected to the corresponding connector on the backplane board If the front flap is not closed properly the connection between the hard drive and...

Страница 38: ...ils are available for installing the subsystem into a rack or cabinet Please contact your system vendor for further details The subsystem should be installed in the rack or cabinet before the hard dri...

Страница 39: ...tatus information can be obtained from the FW The FW is fully described in the Fibre to SATA RAID Subsystem Operation Manual that came with your system Please refer to this manual for further informat...

Страница 40: ...of a number of threatening events occurs These events usually jeopardize the functional and operational integrity of the controller board and must be heeded at all times Events such as a breaching of...

Страница 41: ...five 5 buttons three 3 LEDs and a 16x2 character LCD screen that indicates subsystem status Press the ENT button for two 2 seconds on the initial screen to enter the main menu Press the ESC button to...

Страница 42: ...tus event has occurred OFF indicates that the subsystem and all its components are operating correctly Table 3 2 LCD Panel LED Definitions NOTE During the power up process the LCD panel ATTEN LED will...

Страница 43: ...ctivity on the drive Power Status Green Red GREEN indicates that a drive is installed in the drive tray RED indicates that there is a drive failure Table 3 3 Drive Tray LED Definitions NOTE The contro...

Страница 44: ...o activity on the drive ports 4 P_Fail Partner Fail Amber ON indicates that the partner controller in a redundant controller subsystem has failed 5 C_Dirty Cache Dirty Amber ON indicates that data is...

Страница 45: ...s two 2 LEDs on the top The right LED is to indicate the status of each port see Figure 3 5 while the left LED is nonfunctional and will remind unlighted When the right LED illuminates static green me...

Страница 46: ...le LED Color Status FLASHING Green The power supply has not been turned on The PSU module LED will blink when the subsystem is connected to a power source but not yet turned on Static Green The PSU is...

Страница 47: ...ooling fans will return to low speed 3 3 Audible Alarm Different controller environmental and operational parameters like temperature etc have been assigned a range of values between which they can fl...

Страница 48: ...alarm will sound Upper Threshold Lower Threshold 3 3V 3 6V 2 9V 5V 5 5V 4 5V 12V 13 2V 10 8V CPU Temperature 90 C 5 C Board Temperature 80 C 5 C Enclosure Ambient Temperature 40 C 0 C Table 3 7 Defau...

Страница 49: ...ive a message that says Thermal Shutdown Enter Sleep Mode When the temperature falls back within normal range the battery will resume charging 3 4 I2 C Monitoring Presence detection and the general wo...

Страница 50: ...Galaxy A16F R2422 Installation and Hardware Reference Manual Subsystem Monitoring 3 12 This page is intentionally left blank...

Страница 51: ...both copper and optical connections Copper cable is cheaper but limited to lengths of less than 30m Optical cable can be used over longer distances and have been shown to be more reliable Due to the...

Страница 52: ...ty features however they can still inflict damage 4 1 3 FC Speed Auto detection Speed auto detection is specified by the Fibre Channel standard If a 2Gb s or 1Gb s port is connected to a 4Gb s port it...

Страница 53: ...r of hard drives that should be connected through the drive channels the transfer rates and the mechanical performance of the hard disks should be considered When cabling follow all the Fibre Channel...

Страница 54: ...tware to be installed on the host computer 4 2 4 Redundant Controller Modes Two 2 different redundant controller modes are supported the active standby and the active active mode Active standby If thi...

Страница 55: ...n Different logical groups of drives are mapped to the LUN numbers under a host ID For a multi host operation a logical drive configuration can be mapped to different ID LUN combinations In this case...

Страница 56: ...ort names If a controller fails the surviving controller will avail itself using the failed controller s port names In the event of cable disconnection or RAID controller failure a valid data link thr...

Страница 57: ...h 5 6 CH0 CH1 Auto 4G 2G 1G Speed Selection Speed auto detection is a specified feature of the Fibre Channel standard If one of the devices in the FC AL loop is set to an auto setting it will detect t...

Страница 58: ...ices and or daisy chain other A16F R2422 subsystems The subsystem will automatically validate the dual loop configuration and the RAID controller will activate the enclosure monitoring service accordi...

Страница 59: ...s can be created and made available separately through different ID LUN s on the host ports Configuration 1 Connect the left FC ports from each host connection modules to a dual ported host computer S...

Страница 60: ...ters The dual path connection avoids single point of failure Multiple logical drives or multiple partitions can be created and made available separately through different ID LUN s on the host ports Th...

Страница 61: ...k Configuration 1 The left FC ports of both host connection modules on the A16F R2422 are both connected to a two zone switch or two switches then to host computers The software that came with your sw...

Страница 62: ...all of the components have been installed in the A16F R2422 and the host channels have been connected to the host the subsystem can be powered on 4 5 1 Check List BEFORE powering on the A16F R2422 pl...

Страница 63: ...that have been connected to the A16F R2422 Please refer to the manual that came with your FC device to see the power on procedure Step 2 Power on the subsystems that are not connected directly to the...

Страница 64: ...tire subsystem should be checked to ensure that everything is running smoothly and that there are no complications or malfunctions 1 Controller module LEDs The Controller Ready Host Busy and Drive Bus...

Страница 65: ...ibre to SATA RAID Subsystem Operation Manual for more details NOTE The subsystem has been designed to run continuously If a component fails the fault can be corrected online 4 5 4 LCD Screen When powe...

Страница 66: ...ound scrub are running Step 1 Stop I O access to the system Stop all I O access to the Galaxy subsystem Please refer to the related documentation of your applications Step 2 Flush the cache Locate the...

Страница 67: ...ble WARNING Do not remove a failed component from the subsystem until you have a replacement on hand If you remove a failed component without replacing it the internal airflow will be disrupted and th...

Страница 68: ...eadily at hand and can be quickly installed Removing subsystem components without a replacement can lead to permanent subsystem damage When replacing any hot swappable component caution should be take...

Страница 69: ...e of the most sensitive components in the A16F R2422 All previously stipulated safety precautions see Section 2 3 must be strictly adhered to Failure to adhere to these precautions can result in perma...

Страница 70: ...Module Screws Step 3 Remove the controller module by pressing down the two 2 levers at the back of the controller module The controller module will automatically be eased out of the controller module...

Страница 71: ...ll the DIMM module onto the new controller module making sure that the memory module is securely in place See Section 5 3 Step 3 Install the controller module Make sure the levers at the back of the c...

Страница 72: ...DR RAM DIMM module has been failed or a different size of DIMM module needs to be used the pre installed module must be removed and the new one installed Replacement and installation instructions are...

Страница 73: ...e If the DIMM module is not firmly in place the subsystem will not run and the whole procedure must be repeated 5 3 2 DIMM Module Replacement Procedure NOTE If you are going to replace or upgrade a DI...

Страница 74: ...security and helps minimize the loss of data during power shutdowns Each BBU consists of a bracket battery pack and a PCB board that connects to the backplane board The BBUs are pre installed into th...

Страница 75: ...uiting can occur possibly causing functional defects acid leak and other hazardous results If a BBU leaks gives off a bad odor generates heat becomes discolored or deformed or in any way appears abnor...

Страница 76: ...11 Fastening the BBU Retention Screws Step 4 Reset the subsystem for the new BBU to take effect The LED should start flashing to indicate that BBU is being charged When the BBU is fully charged the L...

Страница 77: ...the chassis To replace a host connection module please follow these steps Step 1 Disconnect the SFP transceiver s that are connected to the host connection module Press the latch on the bottom of the...

Страница 78: ...rew Step 3 Pull out the faulty host connection module and place it on a clean surface See Figure 5 15 Figure 5 15 Removing the Host Connection Module Step 4 Loosen four 4 screws on the host connection...

Страница 79: ...ion Module NOTE A label sticker contents the host connection PCB board serial number is shipped in the host connection module spare part package You may stick it on the back of the metal bracket befor...

Страница 80: ...installed with two 2 460W fully redundant hot swappable PSU modules These modules are located at the rear of the subsystem PSU bracket Each PSU module is permanently mounted in a two level steel brack...

Страница 81: ...RNING Although the PSU modules are fully redundant it is not advisable to run the A16F R2422 with a single PSU module for an extended period of time If the second PSU module fails the subsystem will b...

Страница 82: ...This will dislodge the PSU module from the subsystem Figure 5 23 Pressing Down the PSU Handle Step 5 Use the handle to gently pull the PSU module out of the enclosure See Figure 5 24 Figure 5 24 Disl...

Страница 83: ...n handle is in its down position so that the saddle notches on the lower edges of the handle can lock on to the edge metal brackets along the chassis inner walls Push the PSU into the slot and pull th...

Страница 84: ...y available that can be installed as soon as the failed cooling module has been removed WARNING The latches at the back of the cooling module secure the cooling module into the enclosure If these latc...

Страница 85: ...latches will hold the module in place See Figure 5 28 Figure 5 28 Installing the New Cooling Module 5 8 Replacing a Failed Hard Drive 5 8 1 Hard Drive Maintenance Overview Hot swappable drive trays T...

Страница 86: ...a replacement hard drive readily available before removing the failed drive from the subsystem Do not leave the drive tray slot open for an extended period of time or the normalized airflow will be di...

Страница 87: ...utton at the front of the drive tray See Figure 5 31 The drive tray front flap will automatically be lifted and the drive tray will be dislodged from the chassis Figure 5 31 Opening the Front Flap Ste...

Страница 88: ...es of the drive tray two on each side See Figure 5 33 Figure 5 33 Loosening the Hard Drive Screws Step 6 Remove the hard drive from the drive tray Disconnect the drive from the MUX kit and then remove...

Страница 89: ...rews The MUX kit is secured on a drive tray by two 2 retention screws Turn the drive tray over and remove these screws See Figure 5 35 Figure 5 35 Removing the Retention Screws WARNING The MUX kits ar...

Страница 90: ...over Insert the two 2 retention screws from the bottom of the drive tray These screws will firmly secure the MUX kit to the drive tray and facilitate the installation of the appropriate drive See Fig...

Страница 91: ...ude Operating 12 000 ft Packaged 20 000 ft Power Requirements Input Voltage 100VAC 10A 240VAC 5A with PFC auto switching Frequency 47 63Hz Power Consumption 460W Dimensions Without Front Handles With...

Страница 92: ...MI Shock Half sine Operating 10G peak 11ms duration Non operating 100G 180 in sec 240G 2ms half sine Square 240G 2ms half sine Vibration Operating 5 to 500Hz 0 2G X Y Z Non operating 5 to 500Hz 1 0G X...

Страница 93: ...to 16 channels of 3 0Gbps SATA II Drive Channels All drive channels are pre configured and cannot be changed Cache Mode Write through write back adaptive write policy Cache Memory Pre installed 256MB...

Страница 94: ...sive ambient temperature Cooling Fans Two fans for each unit inside PSU Temperature Operating 0 C to 50 C 32 F to 122 F Storage 40 C to 70 C 40 F to 158 F Humidity Operating 20 to 90 non condensing No...

Страница 95: ...l mode settings are stored on NVRAM Failure Indicator Via audible alarm LCD keypad panel RAIDWatch Manager session event notifications or event prompts on terminal emulation A 7 Fault Tolerance Manage...

Страница 96: ...Galaxy A16F R2422 Installation and Hardware Reference Manual A 6 Specifications This page is intentionally left blank...

Страница 97: ...pe III bezel and Type II LED light pipe 2 to 1 SATA SATA I MUX conversion dual controller subsystems GAL 9273A2DT2S1S Drive tray Type III bezel and Type II LED light pipe 2 to 1 SATA SATA II MUX conve...

Страница 98: ...9 GAL 9270CUPSYCab UPS Y cable audio jack to DB 9 GAL 9270CSFP2GA01 Agilent Fibre Channel 2 125 1 0625 GBd Small Form Pluggable Optical Transceiver LC waive length 850nm multi mode GAL 9270CFCCab01 O...

Страница 99: ...a 20 pin host connector These port sockets receive Small Form Factor SFP fiber optic and copper based transceivers You may contact our technical support for an updated list of SFP transceiver modules...

Страница 100: ...gnal logic 0 indicates normal operation 9 VEER Receiver ground common with transmitter ground 10 VEER Receiver ground common with transmitter ground 11 VEER Receiver ground common with transmitter gro...

Страница 101: ...ller module rear panel for terminal emulation management PN GAL 9270ASCab Figure C 2 RS 232C Audio Jack Pin Outs CN1 Pin Number Pin Name 1 Ground 2 TXD 3 RXD CN2 Pin Number Pin Name 1 NC 2 RXD 3 TXD 4...

Страница 102: ...on dual controller module rear panels for maintenance free terminal emulation management during controller failover failback GAL 9270AYCab Figure C 3 RS 232C Audio Jack Pin Outs CN1 Pin Number Pin Nam...

Страница 103: ...is cable to connect the COM2 serial port to a UPS PN GAL 9270CUPSCab Figure C 4 RS 232C Audio Jack Pin Outs CN1 Pin Number Pin Name 1 Ground 2 TXD 3 RXD CN2 Pin Number Pin Name 1 TXD 2 RXD 3 NA 4 NA 5...

Страница 104: ...Cable Pin Outs Use this cable to connect the COM2 serial port to a UPS PN GAL 9CAB000149G0 Figure C 5 RS 232C Audio Jack Pin Outs CN1 Pin Number Pin Name 1 Ground 2 TXD 3 RXD CN2 Pin Number Pin Name 1...

Страница 105: ...l Modem A null modem is used for wire swap and is necessary for connecting COM1 CN2 to a PC serial port PN GAL 9011 Figure C 5 Null Modem Pin Outs Swap pin 2 and pin 3 Swap pin 4 and pin 6 Swap pin 7...

Страница 106: ...e Reference Manual C 8 Pin Outs C 7 Ethernet Port Pin Outs Figure C 6 LAN Port Pin Outs Pin Pin Name Pin Pin Name 1 LAN_TXP 5 N2 2 LAN_TXN 6 LAN_RXN 3 LAN_RXP 7 N1 4 N2 8 N1 Table C 7 Ethernet Port Pi...

Страница 107: ...Galaxy subsystem D 3 Serial Communication Cable Part Number GAL 9270CUPSCab 0030 GAL 9270CUPSYCab 0030 The A16F R2422 is shipped with a customized audio jack to DB9 serial communication Y cable that...

Страница 108: ...efault baud rate for the COM 2 serial port is 38400 and must be changed to 2400 For instructions on changing the baud rate please refer to the Generic Operation Manual that came with the subsystem D 4...

Страница 109: ...subsystem after the subsystem has been powered on but you will have to trigger the firmware to allow the subsystem to detect the UPS If daisy chain function is applied be sure the make all the cable...

Страница 110: ...y and the UPS has either been disconnected from the AC power supply or the AC power supply has been disrupted The write policy will be changed from the default write back to write through If this mess...

Страница 111: ...Level BPL Write Policy Status UPS connection is absent N A N A Write back UPS connection detected N A N A Write back Warning UPS AC Power Loss detected Disconnected BPL 50 Write through Warning UPS Ba...

Страница 112: ...Galaxy A16F R2422 Installation and Hardware Reference Manual Uninterruptible Power Supply D 6 This page is intentionally left blank...

Отзывы: