Appendix
Troubleshooting
74
CLIPSTER | Hardware Guide | Hardware Generation V+
Rohde & Schwarz DVS GmbH
Troubleshooting
The table below lists some errors that may occur during the oper-
ation of the R&S DVS system and details how to resolve them. If
you experience trouble that cannot be resolved with the solutions
described here or in chapter "Maintenance" (page 53), please
contact your local vendor or R&S DVS directly.
Error
Cause
Solution
Accesses to
the main
storage are
slow.
AND/OR
Drops occurred
during
playout/capture
The data storage
is too full.
It is recommended to use
only 85% of the overall SSD
disk capacity to ensure real-
time capability. If the storage
is too full, delete some of
your data.
Configurations of
the system have
been altered.
Contact the R&S DVS service
department.
One or more
SSD disks of the
SSD disk array
are worn.
Try to identify the worn disk
and replace it as described in
section “SSD Disk Mainte-
nance” on page 54.
A RAID controller
is defective.
If you can rule out the above
mentioned causes, a RAID
controller may be defective.
Contact the R&S DVS service
department.
Содержание CLIPSTER
Страница 1: ...R S CLIPSTER Hardware Guide ...
Страница 4: ... 4 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 20: ...Introduction Important Notes 20 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 46: ...Overview Overview of the Rear 46 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 52: ...Operation Operating the System 52 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 72: ...Maintenance Power Supply Maintenance 72 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 94: ...Appendix Conformity Declarations 94 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH ...
Страница 98: ...98 CLIPSTER Hardware Guide Hardware Generation V Rohde Schwarz DVS GmbH Index ...