E2000
[ Temp control device communication error ]
- Wires breaking down.
- Check communication cable (13-15)
E2200
[ Voltage became caution level ]
- Check input voltage level and power source.
(345VAC-435VAC)
E2300
[ Voltage became abnormality level ]
- System suspended
- Check input voltage level and power source. (325VAC-455VAC)
- Correct cause of the abnormality in factory electricity.
** Contact distributor about errors not mentioned above or not solved by this.
** OTHER MESSAGES;
Error
code
Level
Description
How to recover
Cause
Remarks
E1301
Warn
ing
Disconnection of microphoto sensor
Check wiring on sensor PH1
Check sensor at Maintenance window
Sensor of table original position not detected
E1400
Error
Short circuit error on push key
Check push buttons
E1500
Error
TEMP setting error
Target must be in the range of 0-850c
Target set over 1100c
E1603
Error
TEMP setting error
Target must be in the range of 0-850c
E1604
Error
Main heater TEMP error
Replace heater or thermocouple, check
control system
Present temp is out of range