77-014 - Yasui Rotating Burnout Furnace 37+
49
8-3-4. ELV TIME
Elevation Time, so called “ Rise Time “, “ Raise Time “, “ Ramp Time “ in other words.
The part in yellow (below)
8-3-5. TEMP
Setting Temperature
8-3-6. KEEP TIME
Holding time at each setting temperature.
8-3-7. ROT
You can cancel rotation at required step.
Tapped cell and before that changes to ‘NO’ and the last cell which is set ‘No’ can be switched
‘Yes’ by one tap.
8-3-8. AB
You can cancel After burner heating from required step.
Tapped cell and after that changes NO and first cell with No can be switched Yes by one tap.
RBF37 is shipped with 20 Memories already included with same recipe detail. (next page)
Comment [ Au_and_Ag] is registered to Memory number 00 only.
Other memories have no comment (01-19)
Please choose any Memory number to edit recipe and comment.
You don’t need to register new Memory from blank recipe.