77-014 - Yasui Rotating Burnout Furnace 37+
22
22
3-7. SETTING AUTO DOOR
WARNING
[1] Before connecting tubes for auto door, be sure to set the insert pin to the handle of door to
release the door lock. Removal of the insert pin after the auto door has been installed may cause
unexpected and very rapid opening of the door.
[2] Never stand in front of the door, when air is initially supplied to the auto door, because the
door may unexpectedly and very rapidly open or close.
[3] Never stand in front of the door, when air is once shut off and then supplied again to the auto
door to replace air supply source, because the door may unexpectedly and very rapidly open or
close (because of same reason as above [2])
[4] Do not bend or kink the air supply tube.
3-7-1. RELEASING DOOR LOCK
When the auto door is used, pull the
lever of door handle and insert the pin
as shown in the figure so that the door
will be set to unlocked position.
3-7-2. CONNECTING FOOT PEDAL
Connect as the figure in next page.
Connect the tube from the air supply source to the regulator attached to the auto door control box.
Standard connector is dia. 6 mm tube and instantaneous push-to-connect type. Usual hose
connector also can be used instead.
Connect the foot pedal to the auto door control box.
Position the foot pedal at a convenient area.