12
Gas Requirements
TO INSTALL PRESSURE REGULATOR
1 - Assemble the pressure regulator, mount the 1/2” NPT (conical) male connector and
elbow. connector
2 - Screw the pressure regulator group on the range interposing the gasket supplied.
Pay attention to the vertical alignement (45°) of the same pressure regulator.
GAS CONVERSION WARNING!
Before carrying out this operation, disconnect the appliance from gas and electricity.
Gas conversion shall be conducted by a factory-trained professional. Call the customer
service hotline to identify a factory-trained professional near your home. The gas
conversion procedure for this range includes 3 steps:
1. Pressure regulator
2. Surface burners
3. Adjustment of minimum setting.
The conversion is not completed if all 3 steps have not been concluded properly. Before
performing the gas conversion, locate the package containing the replacement nozzle
shipped with every range.
IMPORTANT
: each nozzle has a number indicating its flow diameter printed on the
body. Consult the table on “Specifications Technical data “paragraph for matching
nozzles to burners. Save the nozzles removed from the range for future use.
Flexible Connections
: if the unit is to be installed with flexible couplings and/or quick-
disconnect fittings, the installer must use a heavy-duty AGA design-certified flexible
connector or at least1/2” (1.3 cm) ID NPT (with suitable strainreliefs) in compliance
with ANSI Z21.41and Z21.69.
G - area for gas connection
E - area for electric connection
In Canada:
CAN 1-6, 10-88 metal
connectors for gas appliances and CAN
1-6.9 M79 quick disconnect devices for
use with gas fuel.
In Massachusetts:
This appliance must
be installed with a 36” (3-foot) long
flexible gas connector.
1