5. Faults
5.1. Fault:
Device does not start.
Cause:
Remedy:
●
Power cable defective.
● Have the power cable replaced by qualifi ed personnel or an authorised
ROLLER customer service workshop (ROLLER’S Scirocco 50). Replace power
cable. (ROLLER’S Scirocco 80).
●
Device defective.
●
Have the apparatus checked/repaired by an authorised ROLLER customer
service workshop.
●
The humidity set on the device is higher than the humidity in the room.
● No dehumidifi cation necessary or correct the humidity setting on the device,
see 3. Operation
●
ROLLER’S Scirocco 50: The condensation tank (9) is not pushed in
completely.
●
Push in the condensation tank as far as it will go.
●
ROLLER’S Scirocco 80: 11.5 l condensation tank (9) (accessory, Art. No.
132100) was inserted incorrectly in the ROLLER’S Scirocco 80.
●
See 2.4.
2
●
ROLLER’S Scirocco 80: Condensation tank switch set incorrectly (5).
●
See 2.3.
2 and 2.4.
22
2
5.2. Fault:
On reaching the humidity set on the device, the device does not switch on or off.
Cause:
Remedy:
●
The controller only switches the device on/off when the humidity exceeds/
drops below the set humidity by 3 % (ROLLER’S Scirocco 80)
.
●
Wait or correct the humidity setting on the device, see 3.
●
Continuous operation is set.
●
Change the operating mode, see 3.
5.3. Fault:
The device switches off although the humidity set on the device has not yet been reached.
Cause:
Remedy:
●
The unit can ice up at cold ambient temperatures and/or in continuous oper-
ation. The icing LED in the ROLLER’S Scirocco 50 lights up (Fig. 6 (18)). In
the ROLLER’S Scirocco 80, the icing symbol (18) appears in the display
(2).
●
In the ROLLER’S Scirocco 50, the fan continues running, the compressor
switches off. After the ice has thawed, the compressor switches back on, the
icing LED goes out and dehumidifi cation/drying continues. ROLLER’S Scirocco
80 is equipped with an automatic hot gas thawing system. This is regulated by
the device. The device starts the dehumidifi cation/drying automatically after
thawing, the icing symbol (18) switches off. Switch off the ROLLER’S Scirocco
80 if icing occurs at short intervals. Wait until the ice has thawed completely.
Then continue dehumidifi cation/drying.
●
Power cable defective.
● Have the power cable replaced by qualifi ed personnel or an authorised
ROLLER customer service workshop (ROLLER’S Scirocco 50). Replace power
cable (ROLLER’S Scirocco 80).
●
Device defective.
●
Have the device checked/repaired by an authorised ROLLER customer service
workshop.
5.4. Fault: The dehumidifi cation performance diminishes.
Cause:
Remedy:
● Air fi lter (Fig. 6 (28)) or air fi lter mat/air fi lter fl ap (Fig. 3 (17)) dirty.
●
Clean/replace parts, see 4.1. Maintenance
●
Using the device reduces the humidity, this also reduces the amount of
condensation.
● Check whether the dehumidifi cation/drying can be set.
5.5. Fault:
In the ROLLER’S Scirocco error messages E1 or E3 are shown in the display (2).
Cause:
Remedy:
● The humidity of the room is outside the measuring range ≤ 30 % or ≥ 90 %
of the ROLLER’S Scirocco 80.
●
Set the device to continuous operation, see 3. Operation
●
Sensor for measuring the humidity is defective.
●
Have the device checked/repaired by an authorised ROLLER customer service
workshop.
5.6. Fault:
In the ROLLER’S Scirocco 80 error messages E2 or E5 are shown in the display (2).
Cause:
Remedy:
●
Sensor for compressor temperature monitoring is defective.
●
Have the device checked/repaired by an authorised ROLLER customer service
workshop.
5.7. Fault:
In the ROLLER’S Scirocco 80, error message E4 is shown in the display (2).
Cause:
Remedy:
●
11.5 l condensation tank (9) (accessory, Art. No. 132100) is full.
●
Empty the 11.5 l condensation tank.
●
Condensation tank switch set incorrectly (5).
●
See 2.3. and 2.4.
5.8. Fault:
ROLLER’S Scirocco 50: Condensation tank LED (6) fl ashes.
Cause:
Remedy:
●
Condensation tank (9) is full.
●
Empty the condensation tank.
5.9. Fault:
ROLLER’S Scirocco 50: Icing LED (18) fl ashes or lights steadily although the compressor is not iced up.
Cause:
Remedy:
●
Device defective.
●
Have the device checked/repaired by an authorised
ROLLER customer service workshop.
Содержание Scirocco 50
Страница 2: ...Fig 3 Fig 1 Fig 2 Fig 4 1 2 13 14 16 6 7 18 15 11 12 1x 4x 2x 8 4 17 3 Max 1 5 10 9...
Страница 3: ...2m Fig 7 Fig 5 Fig 6 28 4 9 20 19 2m Fig 8 WARNUNG 21 15 13 18 6 23 27 24 14 2 22 26 25 WARNUNG 3 21...
Страница 4: ...Fig 9 kWh hh mm 3x 1x 12 6 9 3 3x 1 5 V LR44 AG13 kWh hh mm 8 7 4...
Страница 50: ...50...
Страница 51: ...51...