1-64
LEF2-300
1
R
EPLACEMENT
Ribbon Cable (Main Board to Print Carriage Board) Replacement
18.
Connect the ribbon cables to the main board and signal junction board.
1. Signal junction board CN25
2. Main Board CN14, CN15, CN17
2
1
CAUTION
Connect the ribbon cable from No. 4 to No. 1.
No. 1
No. 2
No. 3
No. 4
shortest ribbon cable
19.
Bundle the cables with the clamps.
Rear view
20.
Connect the ribbon cables to the print carriage board.