2-79
LEF2-300
2
Adjustment
UV Lamp Height Adjustment
9.
Loosen four screws to set the gap between the bottom of the UV lamp stay and the top of the table plate to [7.8 mm].
1. UV lamp stay
7.8 mm
1
10.
Tighten three screws in the order shown in the figure.
CAUTION
Fasten the screws to attach the UV lamp while pushing the UV lamp downward.
1
3
2
11.
Press the [TABLE DOWN] key to set the height to below [100 mm].
12.
Press the [
] key to move the UV lamp backward.
13.
Press the [TABLE UP] key to set the height to [103 mm].
14.
Check that there is no gap between the bottom of the UV lamp and the top of the table plate.
CAUTION
If there is a gap, go back to step 7, and perform the adjustment again.