RP208CN User’s and Installer’s Manual Page 44
either "timed out" or been silenced by the act of system disarming. Be sure to
check with Central Station personnel if restore are permitted and, if so, what
codes are required.
Annotate: When the communicate protocol is CID, separated codes is the same
as restore codes(ABC), input the last 3 digit: OABC;
When the communicate protocol is4+2, the first 2 digit are separated reporting
codes(AB), the last 2 digit are restore reporting codes(CD), total are 4 digit:
ABCD
Hex date fast operation
A=[STAY]+[1] B=[STAY]+[2]
C=[STAY]+[3] D=[STAY]+[4]
E=[STAY]+[5] F=[STAY]+[6]
Locatio
n
Description Num
Digit
Report
Code
32
Zone 1 Alarm Reporting code
3
000
33
Zone 2 Alarm Reporting code
3
000
34
Zone 3 Alarm Reporting code
3
000
35
Zone 4 Alarm Reporting code
3
000
36
Zone 5 Alarm Reporting code
3
000
37
Zone 6 Alarm Reporting code
3
000
38
Zone 7 Alarm Reporting code
3
000
39
Zone 8 Alarm Reporting code
3
000
40
Keypad Fire Alarms Reporting code
3
000
41
Keypad Panic Reporting code
3
000
42
Keypad Special Emergency Reporting
code
3
000
43
Zone 1 Restore code
3
000
44
Zone 2 Restore code
3
000
45
Zone 3 Restore code
3
000
46
Zone 4 Restore code
3
000
47
Zone 5 Restore code
3
000
48
Zone 6 Restore code
3
000
49
Zone 7 Restore code
3
000
50
Zone 8 Restore code
3
000
51
Keypad Fire Restore code
3
000
52
Keypad Panic Restore Code
3
000
53
Keypad Special Emergency Restore
Code
3
000
54
User 0 arm (the "Master" Code,
"Quick Arm" OR "Keyswitch" Arm)0
3
000
55
User 1 arm Reporting code
3
000