RP208CN User’s and Installer’s Manual Page 38
keypad's simultaneously for two seconds.
10
Special Emergency Keying Follow (Latched)
UO is activated immediately when pressing the keypad's [7] and
[8] keys simultaneously for two seconds. UO is deactivated when
the system is disarmed.
11
Special Emergency Keying Follow (Pulsed)
UO is activated for several seconds when pressing the keypad's
[7]
and
[8]
keys simultaneously for two seconds.
12
Duress Code Follow(Pulse)
UO is activated for several seconds (and then deactivates) when
any duress code is entered.
13
Duress Code Follow (Latched)
UO is activated when any duress code is entered.
14
AC Loss Follow (Latched)
UO is activated due to a lack of power from the commercial AC.
UO is deactivated when the system is operating properly from
commercial (AC) power.
15
AC Loss Follow (Pulse) AC
UO is activated for several seconds (and then deactivates) due
to a lack of power from the commercial AC.
16
Low Battery Follow (Latched)
UO is activated due to low power from the backup battery. UO1
is deactivated when the battery is in good condition.
17
Low Battery Follow (Pulse)
UO is activated for several seconds due to low power from the
backup battery.
18
Zone 1 Alarm Follow (Latched)
UO is immediately activated when an alarm occurs on Zone 1.
UO remains active (latched) for the duration of the alarm-even
after the system sounder "times out". UO is deactivated when
Zone 1 goes into normal condition.
19
Zone 1 Alarm Follow(Pulse)
UO is immediately activated for several seconds (pulse) and then
deactivates whenever Zone 1 goes into alarm.
20
Zone 2 Alarm Follow(Latched)
21
Zone 2 Alarm Follow(Pulse)
22
Zone 3 Alarm Follow(Latched)
23
Zone 3 Alarm Follow(Pulse)
24
Zone 4 Alarm Follow(Latched)
25
Zone 4 Alarm Follow(Pulse)
26
Zone 5 Alarm Follow(Latched)
27
Zone 5 Alarm Follow(Pulse)
28
Zone 6 Alarm Follow(Latched)
29
Zone 6 Alarm Follow(Pulse)
30
Zone 7 Alarm Follow(Latched)
31
Zone 7 Alarm Follow(Pulse)
32
Zone 8 Alarm Follow(Latched)