RP208CN User’s and Installer’s Manual Page 43
4 Bell-Siren
NO
YES
5 Bell-Siren
YES
YES
8
Loudspeaker
YES
NO
Location:30
System Controls:( 2
nd
Digit)
2
nd
Digit
3 Minute Bypass
Silent
Panic
Bell Squawk On Arm
0 Enabled
NO
NO
1 Enabled
YES
NO
2 Enabled
NO
YES
3(default) Enabled YES
YES
4 Disabled
NO
NO
Periodic Test Time
:
Location 31
If desired, the RP208CN can send a daily test transmission to the Central Station
to Verify the operation of the Unit's Digital Communicator.
Location:31
Periodic Test Time
Default: 0000
Sets a fixed, daily time for sending an test transmission to the Central Station.
The chosen time is expressed in 24-Hour format (following examples): 8:30
AM=0830 11:15AM=1115, 4:30 PM=1630 If desired, disable the test transmission
capability by accepting (or entering) the default (0000)
Note:
Failure to set the systems' time clock, will prevent the code from being
sent to the Central Station.
Communicator Reporting Codes
:
Locations 32-94
The reporting codes is a report when the system has something happened to
give a report to the alarm center. Different status will send different report.
Reporting Codes for Alarm Events:
To program the codes that will be transmitted by the RP208CN to the Central
Station.
To prevent the corresponding event from being reported, use a "double-zero"(00,
the default) in the location.
Notes on Alarm Restores:
An RP208CN Restore Repot informs the Central Station that the external
sounder's operation, initially triggered by the respective alarm condition, has