RP208CN User’s and Installer’s Manual Page 22
Connect Detector(s)
As the Fig.3 shows, the wiring work must be done without power.
1. Used and unused zone should connect with 2.2k
Ω
termination resistors.
When connecting detector, please install termination resistors in the detector,
to ensure the system of self-protection function.
2. The two ports of ALARM, one for COM port and another for alarm zone ports
respectively on the mainboard.
3. TAMPER ports of detector, connected to tamper zone and COM. When
there are many detectors, TAMPER port in series to access tamper zone and
COM port.
4. "+ DC12V -" in the detector connect AUX and COM respectively. Do not mix
anode and cathode.
5. Please connect the port of UO when need.
Connect Voice Module
As Fig.4, connecting voice module just need to insert it into the connector on
the control panel.
1(record)
-
recording button
2(play)-test record button
3
-
the eligible label including production serial number, tester number,
production type and version number.
4
-
recording microphone