RP208CN User’s and Installer’s Manual Page 21
Install Control Panel and Keypad
The RP208CN control panel should install in the aridity, near by AC power
supply which can't be power off and connect the ground well and be easy to
connect the phone line. Use correct tool, avoiding the damage toward the
equipments.
The keypad is generally installed in the open side of the entry, the height
should be easy to user. The Tamper Button on the back cover of the keypad
can prevent the keypad from being broken or tore down, turn on it and press it
tightly to the wall while installing.
Please connect the 4 lines of the keypad with the main board respectively
according to the red, black, yellow and green sequence. Such as Fig.3 shows.
Connect the Telephone Line
There are two twin ports of telephone lines on the mainboard. The ports which
mark LINE used for input, PHONE for telephone. Such as Fig.3 shows.
Connect the Standby Battery
Please provide a standby battery (DC12V) inside to panel in case of the AC
power is cut off.
Two lines marked BAT link the battery with anode+ (red) and the cathode
-(black) respectively. Such as Fig.3 shows.
Don't conjunction any power before connected all the lines well.
Connect Transformer
The output of transformer should be AC16.5V, connecting into the AC two ports
on the mainboard. When AC power is different, please carefully choose a right
transformer to be applicable to AC220V or perhaps AC110V. Remember: The
red lines for the high -voltage, do not mix with blue which is the low-voltage.
Don't power the system before the installation finished well.
Connect Siren
The port BELL is used for connect siren. Please watch for cathode and anode
when connecting.