Roiscok RP208CN Скачать руководство пользователя страница 1

RP208CN User’s and Installer’s Manual                         Page 1

 

INDEX                               

CHAPTER 1- SUMMARY OF USER’S COMMANDS

 ................................ 3

 

CHAPTER 2 – ABOUT THE KEYPAD

 ..........................................................  4

 

RP208KCL

 

(LCD

 

K

EYPAD

) ................................................................................ 4

 

LED

 

I

NDICATION AND 

K

EYS

 ..................................................................................  5

 

F

UNCTION AND 

O

PERATION

 .................................................................................. 7

 

1. Setting/Changing and Deleting User’s Code

 ................................... 7

 

2. Setting Date and Time

 .........................................................................  9

 

3. Displaying System Date and Time

..................................................... 9

 

4. Setting Follow-me Number

 ................................................................. 9

 

5. Quick Arming

 ...................................................................................... 10

 

6. Code Arming

 ....................................................................................... 10

 

7. Bell Squawk on Arming

 ..................................................................... 10

 

8. Disarming

 ............................................................................................ 10

 

9. On/Off Audible kiss-off

 ........................................................................11

 

10. Duress Disarming

 .............................................................................11

 

11. Cutting off Sounder and Stop Auto-dialing

 ....................................11

 

12. Bypassing/ Un-bypassing a Zone

 ..................................................  12

 

13. Escape Key [ESC]

 ........................................................................... 12

 

14. Emergency Keys

 .............................................................................. 12

 

15. Entry and Exit Delays

 ...................................................................... 13

 

16. 24-Hour Zone

 ................................................................................... 13

 

17. Trouble Display

 .................................................................................  13

 

18. Zone Features

 .................................................................................. 14

 

19. Get Events from Event Logger

 .......................................................  14

 

20. On/Off Door Chime

 .......................................................................... 15

 

CHAPTER 3 - INSTALLATION

 .................................................................... 16

 

B

EFORE 

I

NSTALLATION

 ...................................................................................... 16

 

FAQ.

 OF 

I

NSTALLATION AND 

S

OLUTION

 ............................................................... 16

 

T

HE 

M

AIN 

B

OARD

 ............................................................................................. 17

 

Содержание RP208CN

Страница 1: ... me Number 9 5 Quick Arming 10 6 Code Arming 10 7 Bell Squawk on Arming 10 8 Disarming 10 9 On Off Audible kiss off 11 10 Duress Disarming 11 11 Cutting off Sounder and Stop Auto dialing 11 12 Bypassing Un bypassing a Zone 12 13 Escape Key ESC 12 14 Emergency Keys 12 15 Entry and Exit Delays 13 16 24 Hour Zone 13 17 Trouble Display 13 18 Zone Features 14 19 Get Events from Event Logger 14 20 On Of...

Страница 2: ... 30 CHECK LOCATION DATA 30 ENTRY EXIT PROGRAM 31 A PROGRAMMING TUTORIAL 31 General System Parameters Locations 00 07 32 Installer Code Location 08 10 33 SYSTEM TIME LOCATIONS 11 13 33 INTRUSION ZONE TYPES AND ZONE SOUNDS LOCATIONS 14 21 34 UTILITY OUTPUTS EVENT AND RESULT LOCATIONS22 DEFAULT 00 36 COMMUNICATION PARAMETERS LOCATIONS26 29 39 DIGITAL COMMUNICATOR CONTROLS LOCATIONS 26 DEFAULT 41 39 C...

Страница 3: ...e Set change a user code 5 master code 1 9 new code Set date 6 1 master code MM DD YY Set time 6 2 master code H H M M Auto arm time 6 3 master code H H M M Set follow me phone no 1 7 1 master code phone No 1 Set follow me phone no 2 7 2 master code phone No 2 Set follow me phone no 3 7 3 master code phone No 3 Set follow me phone no 4 7 4 master code phone No 4 On off buzzer 8 master code 1 On of...

Страница 4: ... LED lighted indicators and LCD display Through its keys you can enter commands to Arm and Disarm the system bypass intrusion zones report emergencies stop the siren checking the trouble programming the system and other handling Fig 1 Layout of the RP208KCL Keypad Instruction 1 Power 2 LCD Display 3 Arm 4 Disarm 5 Bypass 6 Fire 7 Tamper 8 Arm key press 9 Stay key press 10 Buzzer 11 Exit Delete key...

Страница 5: ...ggered Statue Explanation System Disarmed System Armed ROISCOK All the zones are secured and working normally Z1 Zone 1 was triggered An alarm has occurred on Zone1 Z2 Zone 2 was triggered An alarm has occurred on Zone2 Z8 Zone 8 was triggered An alarm has occurred on Zone8 3 ARM LED The ARM LED indicates whether or not the system is armed In armed condition the ARM LED is on in case of any violat...

Страница 6: ...ones have been bypassed for more information on bypassing 6 FIRE LED When fired the LED flashing rapidly 7 TAMPER LED When the detector s or the keypad is are tampered or destroyed a Tamper Code report will be sent and the LED will be flashing 8 System Arming ARM When ARM key is depressed all the zones are armed 9 Stay Home Arming STAY Home Arming or Stay Arming allows individuals to remain inside...

Страница 7: ...or arming the external zone is armed while leaves the interior zone disarmed 5 Under the disarmed status press to enter user s function mode Reference to CHAPTER 1 SUMMARY of USER S COMMANDS 1 Setting Changing and Deleting User s Code The default Master Code of RP208CN is 1 2 3 4 Unless your alarm company has already changed it to suit your preference it s best to modify this code to one which is ...

Страница 8: ... the Master Code although it can be changed Step Operation 1 The system must be disarmed Enter the User Functions Mode and choose Codes 5 Press 5 2 Enter the current 4 digit Master Code For example 5 6 7 8 3 To set delete the User Code 1 press 1 To set delete the User Code 2 press 2 To set delete the User Code 3 press 3 The other Codes can be set deleted in the same way 4 Enter the new User Code F...

Страница 9: ...st 18 2006 operate as 6 1 MASTER CODE 08 18 06 6 2 MASTER CODE 16 28 3 Displaying System Date and Time Press 4 to check the system time on LCD keypad And the format should be MM DD YY Hour Minute 4 Setting Follow me Number In case of an alarm event a phone call can be made to one or more predefined phone number There are three different tone types that represent burglary fire and special emergency...

Страница 10: ...re operate it 4 When arming the system there will be one confirmation sound which means the exit delay begin now Then leave here before the exit delay time is over to avoid false alarm The exit delay time is defaulted as 30 seconds 6 Code Arming Your RP208CN offers two methods of arming Quick Arming and Code Arming It s defaulted as quick arm If the user requires code arm it should be set when pro...

Страница 11: ...intruder s wishes while sending a silent duress alarm to the Central Station To do so you must use a special Duress Code Which when used will disarm the system in the regular manner while simultaneously transmitting a silent alarm to the central station All 10 codes including one Master Code and 9 User Codes can activate the Duress disarming by adding 1 to The last digit of your user codes The Dur...

Страница 12: ...ne is bypassed the zone will not be armed when arming When disarming all the bypassed zones will be automatically un bypassed There are two methods of Bypassing Quick Bypassing It s defaulted that all the zones of RP208CN can be set as Quick Bypass Bypass a zone simply press the corresponding key for or above 2 seconds For example to bypass Zone 3 press digit 3 for 2 seconds then By Pass Z3 will b...

Страница 13: ...be set by programming and it s defaulted as 30 seconds To change the delay time refer to location 11 13 of Chapter 5 16 24 Hour Zone RP208CN can support several kinds of zones All other forms of protection including fire and 24 hour panic alarms I e police fire and medical are always ready to report alarms and do not need to be armed 17 Trouble Display When the keypad sends out three short beep re...

Страница 14: ...button which is 24 Hours Zone Fire Zone Used for smoke detector and gas detector which is 24 Hours Zone Tamper Zone Used for connecting with the tamper connector of detector which is 24 Hours Zone Remote Zone Used for connecting with remote receiver which is 24 Hours Zone For user s convenience all RP208CN zones have been defaulted as following Zone 1 Entry Exit Delay Zone Zone 2 Instant Intrusion...

Страница 15: ...e last digit of the event shows the Zone No When the event is disarm or arm the last digit of the event shows the User No 20 On Off Door Chime Assigned to an opening which when violated during the disarmed will cause the system s keypad s to beep once during an alarm the external sounding device will annunciate continuously without interruption When alarm occurs during armed system only the extern...

Страница 16: ...Programmable Read Only Memory technology which stores without the need for a source of power the system s operating program and its programmable parameters System programming may be performed from one or more LCD keypad s designed specifically for that Before Installation You shall read the all the subjects in manual deeply before installation to avoid unnecessary damage to the products Please use...

Страница 17: ...nnected firm and connected the 2 2k ohm resistor correctly when the Siren alarmed under armed state 5 Please check whether the shell of detectors is installed correctly the tamper switch of detector is ready The connect between the port TAMPER on detector and control panel is connected firm and connected the 2 2k ohm resistor correctly when the Siren alarmed under disarmed state 6 Under disarmed s...

Страница 18: ... 24 Z2 for zone 2 and Z3 for zone 3 Defaults as Instant Intrusion Zone 26 Z4 the port for zone 4 defaults as Panic Zone Suit for connect with a panic button 27 Z5 the port for zone 5 defaults as fire zone Suit for connect with a Gas Detector or a Smoke Detector 29 Z6 the port for zone 6 defaults as tamper zone The user should connect it with one of the port TAMPER on detector 30 32 Z7 the port for...

Страница 19: ...RP208CN User s and Installer s Manual Page 19 Fig 2 RP208MB ...

Страница 20: ...RP208CN User s and Installer s Manual Page 20 Fig 3 Connection Instruction ...

Страница 21: ...Telephone Line There are two twin ports of telephone lines on the mainboard The ports which mark LINE used for input PHONE for telephone Such as Fig 3 shows Connect the Standby Battery Please provide a standby battery DC12V inside to panel in case of the AC power is cut off Two lines marked BAT link the battery with anode red and the cathode black respectively Such as Fig 3 shows Don t conjunction...

Страница 22: ... respectively on the mainboard 3 TAMPER ports of detector connected to tamper zone and COM When there are many detectors TAMPER port in series to access tamper zone and COM port 4 DC12V in the detector connect AUX and COM respectively Do not mix anode and cathode 5 Please connect the port of UO when need Connect Voice Module As Fig 4 connecting voice module just need to insert it into the connecto...

Страница 23: ...s following Fig 5 Remote Receiver Connect Wireless Module The function and the port of RP208EW4 expansion wireless module 1 12VDC Power 11 Zone 1 Indicating Light 2 Set Aside 12 Zone 2 Indicating Light 3 Remote Armed 13 Zone 3 Indicating Light 4 Set Aside 14 Zone 4 Indicating Light 5 Trouble Output 15 Receive Data Indicating Light 6 Zone 1 Connector 16 Interfered 7 Zone 2 Connector 17 Setting Indi...

Страница 24: ... 1 6 9 are corresponding 1 4 receiver s channels should be connected 4 of the zones on RP208MB 2 The port 12v should connect to AUX on control panel the GND port to the COM 3 When using remote controller the port 3 should connect switch lock zone of RP208CN 4 In normal the dial 1 and 2 on the dial switch 10 should be set at the position ON Please refer to RP208EW4 User s Manual for more details ...

Страница 25: ...RP208CN User s and Installer s Manual Page 25 Fig 6 The Wireless Receiver ...

Страница 26: ... the control panel As such your system always knows the status of any protected door window hallway room or area The main board of RP208CN is RP208MB The main features of RP208CN include the RP208KCL and RP208MB Main Features Of RP208KCL LCD can display the functions of system 3 Keypad Emergency Zones Panic 1 2 Fire 4 5 Medical 7 8 Key press with Audible Feedback LCD Backlight System Status Displa...

Страница 27: ...et Siren Driver Built in Siren Driver 750mA Clock Built in Digital Clock Siren Voice Output Siren Voice type is Programmable Current output 750mA max Built in Digital Communicator Attached Digital Communicator Compatible with Contact ID 4 2 4 Follow me Phone Numbers 2 Central Station Numbers Code 1 Installation Code 1 Master Code this Code Can Create Duress Code Automatically 9 User Codes Each Cod...

Страница 28: ...on Keypad and Also can be Transmitted to Central Station Battery in Low Power Siren Circuit in Trouble AC Supply in Trouble System Clock is Not Set Tamper Prevention Fire Alarm Circuit Trouble UO Port UO port can be activated when the system is Alarm Arm or Disarm Welcome check the location 22 in Chapter 5 for details Charging of Standby Battery Main Board attaches charging circuit the Standby Bat...

Страница 29: ... output Open collector Active pull down 70mA max Switch zone output 250mA Circuit Response Time 500mS Fuse AUX Auxiliary Power 0 5A Fuse BELL Bell LS Power 1A Fuse BAT Battery Power 2A Dimension weight 80 167mm 0 17kg Keypads LCD Keypad Current consumption 90mA typical 130mA max Control panel connections 4 wire up to 1000M from panel Dimensions 110 130 25mm Weight 0 23kg ...

Страница 30: ...Default jumper is off Keep in disconnection when programming Programming is a process of altering or setting the location data of the control panel RP208CN has 94 locations 01 94 for setting data and each data will correspond to a different function of the control panel The location are made up of 2 digital the data of location are made up of 1 digital 2 digital or many digital RP208CN has the adv...

Страница 31: ...et acquainted with some programming basics a short tutorial has been prepared It involves changing the Installer Code from the factory default of 0 2 0 6 to a sequence of you own choosing If you can master this operation subsequent programming should be easy Operation Action Comments 1 Enter the Programming Mode Enter the factory default Installer Code 0206 A long beep will sound confirming succes...

Страница 32: ...hone number just press the Key To delete an existing phone number simple press the key to enter or replace the phone number required to reach the primary Central Station include all access digits e g 0 to 9 and the area code When done with your complete entry press to store it Up to 20 digits can be entered to the phone number For your records enter the complete phone number above If required incl...

Страница 33: ...e default code observe and modify the first installer s codes modify any phone number nor observe modify MS lock code Location 10 Master Code Default 1234 PUPROSE to establish the keypad code for the system s chief user the Master Code provides the following special privilege 1 Alter the master code and users code 2 Setting the clock 3 Checking the trouble and the events record or other operation ...

Страница 34: ...sed to set the type of the sound Attention Each zone must be connected to an EOL 2 2KΩ resistance when installing even if the zone not in used 1st Digit Zone Type and comment of Zone 1 8 0 Not Used All unused zones should be given this designation lt is also used to disable a zone 1 Enter Exit Delay If violated a zone with this designation will not cause an intrusion alarm during the Entry and Exi...

Страница 35: ...the system an exit delay will follow 2nd Digit Zone sound and comments of Zone 1 8 0 Silent A violation during the armed period will produce no sound The resulting alarm can still be reported to the Central Station 1 default External sounder continuous Cause the external sounding device to annunciate steadily without breaks in the sound cadence the sound will continue until the sounder times out o...

Страница 36: ...ant Intrusion Zone zone type is 21 Zone 4 Panic Zone zone type is 70 Zone 5 Fire Zone zone type is 52 Zone 6 Tamper Zone zone type is 61 Zone 7 Interior Zone zone type is 41 Zone 8 Interior Zone zone type is 41 Special Zones Suggestion a Zone 5 is reserved as a Fire Zone Supports Smoke Detectors and or Gas Detectors A fire zone cannot be disabled or bypassed For fire zone the recommended default z...

Страница 37: ...arm i e intrusion fire keypad initiated panic UO remains active latched for the duration of the alarm even after the system s sounder times out UO is deactivated when the system is disarmed 05 Alarm Follow Pulse UO is immediately activated of several seconds and then deactivated whenever the system goes into any type of alarm i e intrusion fire keypad initiated panic 06 Panic Follow Latched UO is ...

Страница 38: ...tes due to a lack of power from the commercial AC 16 Low Battery Follow Latched UO is activated due to low power from the backup battery UO1 is deactivated when the battery is in good condition 17 Low Battery Follow Pulse UO is activated for several seconds due to low power from the backup battery 18 Zone 1 Alarm Follow Latched UO is immediately activated when an alarm occurs on Zone 1 UO remains ...

Страница 39: ... redial the Central Station after failing to establish a successful communication Voice Module If enabled YES voice messages will be sent If NO then tones will be used to represent an active alarm Location 26 Dialer Controls 1st Digit 1Digit Dialing Method Duty Cycle Redial Central Station 1 Pulse 20 pps 67 33 After 30 seconds 2 Pulse 10 pps 67 33 After 30 seconds 3 Pulse 10 pps 61 39 After 30 sec...

Страница 40: ...on 27 CS Protocols 2 nd Digit 2 nd Digit Date Rate Inter digit Time Date Frequency 0 default 40 pulses sec 390ms 1800Hz 1 33 pulses sec 390ms 1800Hz 2 20 pulses sec 390ms 1800Hz 3 10 pulses sec 390ms 1800Hz 4 40 pulses sec 650ms 1800Hz 5 33 pulses sec 650ms 1800Hz 6 20 pulses sec 650ms 1800Hz 7 10 pulses sec 650ms 1800Hz 8 40 pulses sec 390ms 1900Hz 9 33 pulses sec 390ms 1900Hz A 20 pulses sec 390...

Страница 41: ...Hz Dual round 390 10 Radionics Extended 40 1400Hz Dual round 390 40 Radionics Extended 40 2300Hz Dual round 390 50 Radionics 40 1400Hz Parity 390 20 Radionics 40 2300Hz Parity 390 30 Radionics Extended 40 1400Hz Parity 390 60 Radionics Extended 40 2300Hz Parity 390 70 CS Protocols Location 28 default 03 When selecting 01 the contact ID format all the reporting codes will be automatically applied t...

Страница 42: ...e AUDIBLE at the External Sounder and visual on the keypad If YES the panic alarm will be INAUDIBLE at the External Sounder and invisible on the keypad and there will be no audible kiss off Bell Squawk On Arming If selected Bell Squawk on Arming will produce a brief confirmation chirp from the system s external sounder s once the system is armed and the Exit Delay expires 3 Minute Bypass Enabled I...

Страница 43: ...llowing examples 8 30 AM 0830 11 15AM 1115 4 30 PM 1630 If desired disable the test transmission capability by accepting or entering the default 0000 Note Failure to set the systems time clock will prevent the code from being sent to the Central Station Communicator Reporting Codes Locations 32 94 The reporting codes is a report when the system has something happened to give a report to the alarm ...

Страница 44: ... code 3 000 33 Zone 2 Alarm Reporting code 3 000 34 Zone 3 Alarm Reporting code 3 000 35 Zone 4 Alarm Reporting code 3 000 36 Zone 5 Alarm Reporting code 3 000 37 Zone 6 Alarm Reporting code 3 000 38 Zone 7 Alarm Reporting code 3 000 39 Zone 8 Alarm Reporting code 3 000 40 Keypad Fire Alarms Reporting code 3 000 41 Keypad Panic Reporting code 3 000 42 Keypad Special Emergency Reporting code 3 000 ...

Страница 45: ...ser 9 disarm Reporting code 3 000 74 Auto ARM report code 3 000 75 Forced arm when the system is armed with a bypassed zone Reporting code 3 000 76 Stay arm when the system is armed to the Stay At Home mode Reporting code 3 000 77 Duress Disarm 3 000 78 Daily test Report Code sent everyday at the time specified in Location 24 3 000 79 Low Battery Reporting code 3 000 80 Loss of AC Power for at lea...

Страница 46: ...nd Installer s Manual Page 46 91 Zone 5 Bypass Restore Reporting code 4 ABCD 92 Zone 6 Bypass Restore Reporting code 4 ABCD 93 Zone 7 Bypass Restore Reporting code 4 ABCD 94 Zone 8 Bypass Restore Reporting code 4 ABCD ...

Страница 47: ...Restore 114 Pipeline zone alarm Restore 116 Fire zone alarm Restore 117 Warning sound alarm 122 Warning sign alarm 123 Perimeter zone alarm Restore 131 Interior zone alarm Restore 132 Daytime nights zone alarm Restore 135 Open zone alarm Restore 136 System zone alarm Restore 140 Detector tamper zone alarm Restore 144 24 hours zone alarm Restore 151 gas fired alarm 151 gas fired alarm Restore 151 L...

Страница 48: ... Medical treatment emergency alarm 120 Medical treatment emergency Restore 120 menace alarm 121 Menace Restore 121 Fault reporting AC fault 301 AC Restore 301 Battery power low 302 Battery power Restore 302 Warning sign fault 321 Warning sign Restore 321 Fire zone fault 373 Fire zone Restore 373 On off reporting User arm 6A 401 User unarm 6A 401 User 0 quick arm unarm 62 408 Force arm 63 574 perio...

Страница 49: ... Settings 16 Zone 3 Settings 17 Zone 4 Settings 18 Zone 5 Settings 19 Zone 6 Settings 20 Zone 7 Settings 21 Zone 8 Settings 22 Utility Output 23 24 25 26 Dialer Controls 27 CS Protocols 1 28 CS Protocols 2 29 30 System Controls 31 Periodic Time Set 32 Zone 1 Alarm 33 Zone 2 Alarm 34 Zone 3 Alarm 35 Zone 4 Alarm RP208CN Installer Programming Worksheet Customer Address City State Zip Customer Phone ...

Страница 50: ...ode Zone 8 51 Restore Kpd Fire 52 Restore Kpd Panic 53 Restore Kpd SP 54 User 0 Arm 55 User 1 Arm 56 User 2 Arm 57 User 3 Arm 58 User 4 Arm 59 User 5 Arm 60 User 6 Arm 61 User 7 Arm 62 User 8 Arm 63 User 9 Arm 64 User 0 disarm 65 User 1 disarm 66 User 2 disarm 67 User 3 disarm 68 User 4 disarm 69 User 5 disarm 70 User 6 disarm 71 User 7 disarm 72 User 8 disarm 73 User 9 disarm 74 Auto ARM 75 Force...

Страница 51: ...re Code AC Loss 85 Restore Code Fire Tbl 86 Restore Code Bell Loop 87 Zone 1 Bypass Restore 88 Zone 2 Bypass Restore 89 Zone 3 Bypass Restore 90 Zone 4 Bypass Restore 91 Zone 5 Bypass Restore 92 Zone 6 Bypass Restore 93 Zone 7 Bypass Restore 94 Zone 8 Bypass Restore Phone1 Phone2 ...

Отзывы: