Interface Description
R&S
®
TS-PWA3
66
User Manual 1157.8143.12 ─ 17
8.5
External Analog Interface
8.5.1
Analog Bus Connector X2
The analog bus connector X2 is located at the back of the R&S TS-PWA3 and is con-
nected to analog bus connector X21 on the analog bus backplane.
Only the cable TS-PK01 1166.4147.02 is allowed to be used with the analog bus con-
nector X2.
Shock Hazard
The production test platforms R&S CompactTSVP and R&S PowerTSVP are designed
for operating voltages up to 125 V. When working with high voltages, this voltage can
apply to the analog bus connector X2. Therefore, the cable TS-PK01 must be always
connected on both sides with the test systems R&S
CompactTSVP and R&S
Pow-
erTSVP.
Test applications using hazardous active voltages (above 30 V r.m.s and 42,4 V peak
or 60 V d.c) must be operated by a skilled person only. The appropriate regulations
governing work carried out on electrical equipment must be complied with.
Figure 8-22: Analog Bus Connector X2 (Mating Side)
Table 8-14: Assignment of X2
Pin
Signal
1
GND
2
ABc1
3
GND
4
ABc2
5
GND
6
ABa2
External Analog Interface