Description
R&S
®
TS-PWA3
32
User Manual 1157.8143.12 ─ 17
Figure 3-18: R&S TS-PSYS2 1157.9910.20
Table 3-9: Connectors on the R&S TS-PSYS2
Symbol
Use
X20
Rear I/O
X30
Front Connector
X40
Jumper field Rear I/O signals
3.4.5
Functional Description of the R&S TS-PSYS2
3.4.5.1
Control
The R&S TS-PSYS2 is controlled via CAN.
The CAN lines are terminated manually with a jumper on the R&S TS-PSYS2 (see
Chapter 8.4, "Interfaces of the R&S TS-PSYS2"
3.4.5.2
System Functions
The system functions are implemented by an 8 bit microcontroller which operates at a
10 MHz system speed. It communicates with the system controller in the Com-
pactTSVP or PC across the CAN1 port. The following functions are available:
●
8 x enable of PXI trigger signals to the outside (e.g. PowerTSVP)
●
4 x optocoupler outputs (for PLC or handling systems)
System Module R&S TS-PSYS2