R&S®SML / R&S®SMV03
Stereo Modulation (Option R&S SML-B5)
1090.3123.12 4.27
E-6
EON-DEL
Description:
Enhanced Other Networks:
deletes the complete EON with PI=xxxx.
Command: EON-DEL=xxxx
Value range:
xxxx = 0000 to FFFF (ASCII coded hexadecimal numbers))
Example: STEReo:DIRect
“EON-DEL=1000“
Deletes the EON with PI=1000.
EON-PI
Description:
Enhanced Other Networks:
creates a new EON or reads the list of the program identification (PI) codes of all
EONs created so far.
Command: EON-PI=xxxx
Query: EON-PI?
Response: xxxx,...
Value range:
0000 to FFFF (ASCII coded hexadecimal numbers)
Example:
Command:
STEReo:DIRect
“EON-PI=1000“
Creates a new EON with PI=1000.
Query:
STEReo:DIRect?
“EON-PI“
Response:
"1000"
Note:
A four-digit value must always be set.
Leading zeros, if any, must also be specified.
A maximum of eight EONs can be created.
EON-PS
Description:
Enhanced Other Networks:
sets the program service (PS) name for the EON with PI=yyyy.
Command: EON-PS=yyyy,xxxxxxxx
Query: EON-PS,yyyy?
Response: xxxxxxxx
Value range:
xxxxxxxx = 8 ASCII characters
yyyy = 0000 to FFFF (ASCII coded hexadecimal numbers)
Example:
Command:
STEReo:DIRect
“EON-PS=1000,Test 123“
Sets the program service name for the EON with PI=1000 to "Test 123".
Query:
STEReo:DIRect?
“EON-PS,1000“
Reads the program service name of the EON with PI=1000.
Response:
"Test 123"
Note:
An eight-digit value must always be set. Blank spaces, if any, must also be entered,
otherwise the value will not be accepted.
Содержание SML01
Страница 4: ......
Страница 14: ......
Страница 22: ......
Страница 32: ......
Страница 34: ......
Страница 36: ......
Страница 38: ......
Страница 40: ......
Страница 42: ......
Страница 44: ......
Страница 56: ......
Страница 62: ......
Страница 77: ...R S SML R S SMV03 Menu Summary for R S SML 1090 3123 12 E 6 3 15 Menu Summary for R S SML ...
Страница 78: ...Menu Summary for R S SMV03 R S SML R S SMV03 1090 3123 12 E 6 3 16 Menu Summary for R S SMV03 ...
Страница 148: ......
Страница 240: ......
Страница 242: ......