Installation and Commissioning
R&S
®
ATS1000
42
Instructions Handbook 1179.2983.02 ─ 01
Do not touch the positioner. Close the door.
9.
WARNING!
Risk of personal injury. See
"Positioner moves with high torque"
on page 12.
If the interlock has failed the test or the test result is unclear, do not use the cham-
ber until an
repeats the test.
10. If the interlock fails the test again, take the following steps:
a) Stop work at the chamber immediately.
b) Take the chamber out of commission to make sure that nobody else can use it.
See
Chapter 10.1, "Taking Out of Commission"
c) Contact Rohde
&
Schwarz customer support.
See
Chapter 9.3, "Contacting Customer Support"
Testing Safety Systems