Example:
DIAG:SERV:MOD:TEMP? (@F01M03,F01M05)
Reply
2.01,2.01
This reply shows a temperature reading of 24.85
°C for module
03 and 25.07
°C for module 05, both in switch unit 01.
Usage:
Query only
DIAGnostic:SERVice:USER:ERRor?
Queries for device errors that were not necessarily evoked by a remote control com-
mand. Typically, use this query for errors that may have come up during booting.
Example:
DIAG:SERV:USER:ERR?
Reply:
0,"No error"
Usage:
Query only
Manual operation:
See
DIAGnostic:SERVice:USER:WARNing?
Queries for device warnings that were not necessarily evoked by a remote control
command. Typically, use this query for warnings that may have come up during boot-
ing.
Example:
DIAG:SERV:USER:WARN?
Reply:
-1000,"Options invalid:|K0 not yet in
activation phase"
Example:
DIAG:SERV:USER:WARN?
Reply:
1,"Service firmware.|This firmware
provides elevated access rights needed by the
R&S service.|However this means a certain
security vulnerability of the device.|Please
reboot into an official customer firmware."
Usage:
Query only
Manual operation:
See
8.9
Legacy System Commands from R&S
OSP1x0
The following commands are implemented only for providing compatibility with
setups of the legacy switch units R&S
OSP120, R&S
OSP130 and
R&S
OSP150. Refer to the operating manual of these switch units for more informa-
tion.
DIAGnostic:SERVice:STESt:RESult?
............................................................................... 294
.............................................................................................. 295
Legacy System Commands from R&S
OSP1x0