Installation and Operation Manual 90DIB500IM02 – 5.2
127
DIB-500 R4.1
Commissioning
Function tests DIB-500 R4.1
Table 5.18 provides an overview of possible alarm statuses and the corresponding
alarm indicators of connected external alarms. The visual indicators are displayed in the
area for displaying external alarms in the system controller display window.
The procedure for checking the operating statuses (voltage supply unit) is described in
the following.
Proceed as follows to check operating statuses of the voltage supply unit:
Preparation:
✓
The electrical connection must be made and commissioning completed.
Carry out the following steps:
1. Check the LEDs of the system controller as well as of the AC voltage supply mod-
ules (if available).
Figure 5.33 Front view of the voltage supply unit
2. Check the display window of the system controller.
Figure 5.34 System controller display window
✓
The function test has been completed.
Table 5.18 Alarm states and alarm indicators (system controller)
Alarm state
Visual indicator
Acoustic indicator
A state cannot be dis-
played
---
MINOR
Acoustic signal every two seconds.
CRITICAL/MAJOR
Continuous acoustic signal