PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
26
One long signal
continuously
repeated
♫
♫
♫
♫
… and so on
Memory contents corrupted or MASTER card not
programmed - memory reset necessary. This signal is
accompanied by the steady lit LED SYSTEM.
Legend:
♫
- one long audible signal
♪
- one short audible signal (beep).
Table 7. LED indication.
LED
STATUS
LED OPEN
LED
SYSTEM
Meanings
Steady
(green)
— —
Controller is
Disarmed
.
Steady
(red)
— —
Controller is
Armed
.
Steady
(green)
— Steady
Controller is in the
User Programming
mode.
Flashing
(green)
— Flashing
Controller is waiting for next step during the
User Programming
mode.
—
—
Flashing
Controller is waiting for an identifier.
— Steady —
The door lock is activated; this LED remains ON as long as the
door lock is energized.
— —
Steady
The memory contents corrupted or MASTER identifier not
programmed. This situation is accompanied by acoustic signal
repeated in sequence: sound 2s/pause 2s.
Blinking Blinking Steady
The controller is being programmed from PC, the LED STATUS and
OPEN are blinking along with data send/received by a device.
8.
Appendix
Table 8. Connection cable assignments.
Wire Color
Label
Description
Red
+12V
Supply input plus.
Black
GND
Supply input minus.
Pink
IN1
Input line, internally pulled up to the supply plus through a 5,6K resistor.
Blue
IN2
Input line, internally pulled up to the supply plus through a 5,6K resistor.
White-Yellow
IN3
Input line, internally pulled up to the supply plus through a 5,6K resistor.
Red-Blue
COM
Grey-Pink
NC
Relay output contacts, 1A/24V DC/AC rated:
COM – common