10
•
Card and PIN
, controller requires card and PIN, both of them are necessary for
the successful identification.
Some of the control commands requiring double use of user identifier (e.g.
rearming of a reader by the TOGGLE).
Note: The actual
Identification Mode
specifies user identification method on both:
the controller and the additional reader connected to the controller. It is not
possible to define
Identification Mode
individually for a controller and for additional
reader.
4.5.
Armed and Disarmed Modes
The PR311-BK has two working modes:
Armed
and
Disarmed
. The actual working
operating mode of the controller is indicated on the dual color LED STATUS, which
lights in red for
Armed
and green for
Disarmed
. Generally, the
Armed
and
Disarmed
modes are dedicated to integration of the controller with the alarm system which
protects the same room or area supervised by the access controller, nevertheless
they can be used for any other control purpose which requires an On/Off control
method. The integration with the alarm system (or another device/system) requires
one output line to be configured to the function no. 0 (
Disarmed mode
) and
optional input line configured to the function no. 13 (
Disable arming
). The
controller’s output line (function no. 0) indicates current operating mode of the
controller, whereas the input line (function no. 13) verifies if the controlled system
(or device) can be
Armed
(or set ON) or not. When the installer doesn’t define any
controller’s input to the function no. 13, the controller assumes that the controlled
system or device is always ready for arming and switches to
Armed
mode
unconditionally.
Note: Although the
Armed
and
Disarmed
modes of the controller were designed for
integration with the alarm system they can be used for any other purpose which
requires an on/off method of control (light control, heating control etc).
Note: Either upon powering on or Memory Reset reader automatically enters the
Armed mode. After exit from programming mode reader returns to arming mode
(either Armed or Disarmed) it was before entry to the programming.
4.6.
Arming and Disarming of the Controller (Rearming)
The action changing the controller from
Armed
to
Disarmed
and back (i.e. reverse
direction) is referred to hereinafter as
“rearming”
. The term “arming” should be
understood here as the action effecting a switch into the
Armed
mode, whereas the
term “disarming” a switch into the
Disarmed
mode.
Controller PR311-BK can be rearmed in few methods listed below:
•
by the input line configured to function no. 3:
Disarm steady switch
•
by the input line configured to function no. 61:
Arming/Disarming
momentary switch