PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
20
5.
Programming
The programming of a PR311-BK is divided into two separate parts:
•
User Programming
•
Installer Programming
The
Installer Programming
is intended to configure the unit for specific installation
environment and can be carried out from PC computer only.
The
User Programming
is mainly dedicated to maintain Cards and PIN’s but it is
also designed to provide some other user commands. The
User Programming
can
be carried out remotely from PC or locally by means of
Programming Cards
.
5.1.
Programming Cards
The
Programming Card
is an ordinary proximity card or tag which was assigned for
specific user function. Up to 32
Programming Cards
can be defined in PR311-BK,
each
Programming Card
may have assigned only one programming function but
many
Programming Cards
may be assigned to a single user programming function.
The
Programming Cards
are defined during the initial installer’s setup and can be
carried out from PC only.
Note: The use of
Programming Cards
is restricted to controller only, it is not
possible to use the
Programming Cards
from the external reader connected to the
controller.
5.2.
Memory Reset - Programming MASTER Identifier
The
Memory Reset
Procedure clears entire contents of the PR311-BK memory and
restores default factory settings. During this procedure the new MASTER identifier
and the new controller ID number (address) can be programmed.
The
Memory Reset
consists of the following steps:
•
Power down the unit
•
Remove all connections from CLK and DTA lines
•
Make connection between CLK to DTA lines
•
Restore power, the unit will generate a continuous beep
•
Wait until the LED OPEN (green) starts flashing
•
Disconnect CLK from DTA
•
Present any a proximity card or tag to a unit, it will be a new MASTER identifier
•
Once the previous step is completed controller will generate signal OK and then
will enter the
Armed
mode
If the
Memory Reset
is not accomplished successfully or the content of controller’s
memory is corrupted then after power up the unit will signal memory error (LED