PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
8
•
Identification Mode
can not be controlled by the time schedules
•
Events can not be recorded
Note: All this features listed above are available when the controller operates in
Integrated Access Control System
.
4.
Functional Description
4.1.
Users
Note: Despite of not having a keypad, the PR311-BK allows to assign PIN
code for every user registered in the controller. Programming of a PIN
code for a user(s) in PR311-BK can be carried out from PC computer only
and have practical sense if:
a)
the PR311-BK operates with an additional reader equipped with
keypad (e.g. PRT12)
b)
the PR311-BK operates in an access system together with other
controllers which are equipped with keypads, in this case the same list
of users (with cards and PIN’s) is used for each controller in a system
regardless of a fact that some of them have not a keypad.
The PR311-BK can register up to 1.000 users. Every user has his ID (identification)
number from 001 to 999 and may have card and/or PIN. The PIN codes may have
from 3 to 6 digits and whenever entered PIN code must be followed by [#] mark
which is used to mark the end of a code. The PR311-BK controller precludes
assignment of the same cards or PIN’s for two different users. Users can be
identified by cards, PIN’s or both methods simultaneously. The method of user
identification depends on the actual
Identification Mode
valid on the controller. The
PR311-BK controller supports four types (classes) of the users: MASTER, TOGGLE,
TOGGLE LTD and NORMAL. Each of the class has different authorization for
programming, unlocking and rearming of a controller.
Table 1. User types (User classes).
User Types
Authorization
MASTER
This user is allowed to unlocking the door and to switching the unit between
Armed
and
Disarmed
modes. The MASTER user is defined during
Memory Reset
and is mainly dedicated for the initial testing of a unit.
TOGGLE
This user is allowed to unlocking the door and to switching the unit between
Armed
and
Disarmed
modes.
TOGGLE LTD
This user is only allowed to switching the unit between
Armed
and
Disarmed
modes.
NORMAL
This user is only allowed to unlocking the door.