PR311-BK fv102 Rev B. ENG.doc.DOC
8/9/2006
_________________________________________________________________________________________
_________________________________________________________________________________________
Page
9
Note:
In the PR Master program which is used for programming of a PR311-BK
(and other PR series access controllers) the TOGGLE and TOGGLE LTD class of
users are called respectively: SWITCHER and SWITCHER LTD.
4.2.
Managing of Users
Generally, management of the users in PR311- BK can be provided locally by the
Programming Cards
or remotely from the PC. It is strongly recommended to use
only one of the two mentioned methods. The simultaneous use of local and remote
method of programming may create confusions. For example, users added to
controller manually will
not exist
in the PC database, as a result every programming
from PC it will clear manually added users.
Note: The manual programming of users doesn’t allow to specify the ID number of
a newly enrolled user. As a result users added to a controller can not be removed
later from the controller by indication of theirs ID numbers.
4.3.
Access Groups
When the PR311-BK controller is a part of
Integrated Access Control System
supervised by the Host device, users registered in controller can be divided into 256
Access Groups
. The users which belong to the same
Access Group
have the same
access authorization within system. The access level of each group can be
controlled by the time schedules. The PR311-BK allows to be defined up to 32
different time schedules for a unit. The time schedules consists of one or more time
periods within which users will have access to specified
Access Zone
. The access
rights are defined separately for each
Access Groups
and individually for each
Access Zone
.
Note: There is no practical sense to define
Access Zones
in the small installations.
Instead of this it should be assume that in the small system every
Access Zone
is
equal to a single door.
Note: Users registered in PR311-BK can be divided into the
Access Groups
only
when controller operates in the
Integrated Access Control System
.
4.4.
User Identification
The PR311-BK recognizes the users by theirs identifiers. In PR311-BK each user
programmed in the controller may have card and eventually PIN. The method which
controller uses for user’s identification depends on the actual
Identification Mode
.
The PR311-BK enables following
Identification Modes
:
•
Card Only
, controller accepts only cards
•
PIN Only
, controller accepts only PIN’s
•
Card or PIN
, controller requires card or PIN, only one of them is necessary for
the successful identification