10
GB
11
www.roco.cc
GB
The following table lists all the variable Route-Control parameters:
Programming turnout decoders
Programming of the turnout drive 42624
red housing with both ROCO-Lokmaus
®
-
Systems:
1. Connect Lokmaus
®
and RouteControl to the
Central unit/or amplifier;
2. Activate power supply;
3. Select the desired turnout address;
4. Press the emergency stop key of the Lokmaus
®
.
At Lokmaus
1
®
(10750) the red LED will blink,
at Lokmaus
2
®
(10760) and the RouteControl
the display will blink;
5. Connect green cable of the turnout drive with one
of the two rails (attach contact rail connector);
6. Press the emergency stop key of the Lokmaus
®
.
LED at Lokmaus
1
®
will again be continuously
illuminated. The display of the Lokmaus
2
®
does
not blink any more;
7. Press “ok“ key of the RouteControl;
8. Remove the green wire of the turnout drive
from the rail.
Programming of the turnout drive 42624 red
housing with the Lenz System:
1. Connect both LH 100 and the RouteControl to
the Central unit;
2. Activate power supply;
3. Select the desired turnout address with the
RouteControl;
4. Press the stop key and then “F“ AND “0“ of
the LH 100. The display of the RouteControl will
blink; at the LH 100 first “Stop“ and “Aus* F0“
will appear alternating, then “Aus“;
5. Connect green cable of the turnout drive with one
of the two rails (attach contact rail connector);
6. Again press the stop key of the LH 100. Displays
parameter range of
values
defaul value description
C0
1-31
3
DataBUS address
C1
4-256
256
permissible number of turnouts (with „Maus-Bus“ operation
only 128 at most!)
C2
4-32
32
permissible number of track routes
C3
0/1
1
set of turnouts erasable (1) or not (0)
C4
1-9
2
time required for automatic completion of a numerical input
C5
0,1-9
5
time required for call-up of the track route editor when
pressing the „esc“ key. The value 0 deactivates the key for
this purpose (=child latch)
C6
1-3
3
scroll mode: cursor keys are active only for turnouts when set
to (1), only track routes when set to (2), both turnouts and
track routes when set to (3). The numerical keyboard is not
influenced by this setting
C7
0/1
0
when set to (1) will reset all menu settings and cancel all
track routes
C8
1-30
2
response time in 100ms
C9
1-30
8
dely time between two switching operations in 100ms
CA
0/1
1
DataBUS automatic configuration: 1=on, 0=off
Cb
??
2.0
software version READ ONLY
CC
??
3.0
DataBUS version READ ONLY
Cd
0-119
119
number of turnouts which can still be added to a track
route. This number will be computed automatically by the
RouteControl depending on the already programmed track
routes READ ONLY