Chapter 2 Install the Monitor
9. Tighten the cable tie so it is snug against the terminal wires (D in
10. Use cutting pliers to cut the excess part of the cable tie (E in
11. Install the white label supplied with the kit (F in
12. Align and install the other connector clamp half to complete the assembly
(G in
).
13. Reconnect the DC terminal block with the connector assembly to the
).
Torque the DC terminal block flange screws to the values in
.
14. Turn on the main power switch or breaker.
Figure 6 - Assembly Sequence for DC Power Connector
Connect AC-powered
Monitors
Operate VersaView 6300M AC-powered
monitors in an industrial or control room
environment that uses some form of power
isolation from the public, low voltage mains.
To connect AC power to the monitor,
perform the following steps.
1. Connect the appropriate end of a
customer-supplied power cable to the
power input port on the monitor.
2. Connect the other end of the supplied power cable to an AC power source
with an input voltage of 100…240V AC, 50/60 Hz.
3. Turn on the power switch in the power input port of the monitor.
The white label can be used for identification or other information.
When installed correctly, both tabs of the clamp halves lock into place.
D
A
B
DC Terminal
Block
–
+
C
F
G
+
–
H
E
Ground Screw
IMPORTANT
AC-powered monitors cannot be used in hazardous locations.
IMPORTANT
Use a three-prong, three-slot AC power cord that is rated IEC-320-C13.