Chapter 2          Install the Monitor

Panel Monitor Mounting

For VersaView 6300M monitors that can be panel mounted, perform the 
following steps.

Panel Mounting Requirements

Follow these requirements to mount the VersaView 6300M panel monitor.

Choose a suitable mounting height.

To help prevent overheating and to provide access to the I/O ports for 
cable connections, mount the monitor so there are the following 
minimum clearances:
- X and Z directions: 7 cm (2.75 in.)
- Y direction: 10 cm (3.94 in.)

For optimal performance, mount the monitor in the horizontal 
orientation and vertical (upright) position, so the I/O ports face down.

Enclosure Requirements

The enclosure must provide sufficient space around air inlets and outlets 
to provide the circulation necessary for cooling. For further information, 
see 

Panel Mounting Requirements

 on this page. Never allow air passages 

to become obstructed.

Hot air rises. The temperature at the top of the enclosure is often higher 
than the temperature in other parts of the enclosure, especially if air is 
not circulating.
Consider a user-supplied fan, heat exchanger, or air conditioner for heat 
generated by other devices in the enclosure. See 

Installation Guidelines 

on page 15

 for the acceptable temperature ranges for these monitors.

IMPORTANT

For 6300M panel monitors in non-hazardous locations:

The vertical position can be tilted up to 20° forward or 20° backward 

from the upright position. However, this acceptable tilt angle range 

decreases the maximum operating air temperature to 45 °C (113 °F).

For 6300M panel monitors in hazardous locations:

The vertical position must always be in the upright position; there is 

no acceptable tilt angle.

Y

Y

X

X

Z

Horizontal Orientation

(I/O Ports Face Down)

Vertical 

(Upright) 

Position

(preferred)

20° 

max

20°

max

IMPORTANT:

 This acceptable tilt 

angle range applies only to 6300M 

panel monitors in 

non-hazardous locations.
6300M panel monitors for 

hazardous locations cannot be 

tilted.

Содержание Allen-Bradley VersaView 6300M Series

Страница 1: ...User Manual Original Instructions VersaView 6300M Panel Monitors Bulletin Number 6300M...

Страница 2: ...ibed in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use not...

Страница 3: ...ereux 16 Panel Monitor Mounting 17 Panel Mounting Requirements 17 Prepare the Panel Cutout 18 Required Tools for Panel Installation 18 Panel Mounting the Monitor 18 Connect Peripheral Cables to the Mo...

Страница 4: ...mber 2021 Table of Contents Chapter 4 Clean the Monitor Clean the Display 31 Clean Monitor Labels 31 Clean All Vent Holes 31 Remove Paint and Grease from Bezel 32 Chapter 5 Troubleshoot the Monitor Sh...

Страница 5: ...6300M xxxAXPS Stainless Steel True Flat Resistive 16 9 6300M xxxCXPS 6300M xxxBSPS 4 3 6300M xxxDSPS 6300M xxxACPS Aluminum glass True Flat PCAP 16 9 6300M xxxCCPS Resource Description VersaView 6300M...

Страница 6: ...6 Rockwell Automation Publication 6300M UM001A EN P December 2021 Notes...

Страница 7: ...widescreen formats Analog resistive or projected capacitive PCAP touch screens the latter for multi touch operation Available in display sizes between 8 4 24 inches Resolutions that include FHD VGA S...

Страница 8: ...xxxBAPS 12 1 Resistive 4 3 1024x768 XGA 600 Aluminum Yes No 6300M xxxDAPS Yes 6300M xxxBBPS Aluminum True Flat No 6300M xxxDBPS Yes 6300M xxxBSPS Stainless Steel True Flat 2 No No 6300M xxxDSPS Yes 6...

Страница 9: ...xxxBSPS Stainless Steel True Flat 2 No No 6300M xxxDSPS Yes 6300M xxxAAPS 21 5 Resistive 16 9 1920x1080 FHD 300 Aluminum No No 6300M xxxCAPS Yes 6300M xxxAXPS Stainless Steel True Flat 2 No 6300M xxxC...

Страница 10: ...e 1 VersaView 6300M Monitor Hardware Features 1 2 3 5 7 6 DC Power Models AC Power Models 1 8 Bottom of Standard Panel Monitor Chassis 1 2 3 5 7 6 4 DC Power Models AC Power Models 1 Bottom of Long Di...

Страница 11: ...rts on front bezels of 6300M xxxBA and 6300M xxxBB monitors are not for use in hazardous locations 3 USB HUB port Type B No Description No Description 1 RVL 1 1 Remote video link Requires specific Eth...

Страница 12: ...1 77 17 5 0 69 4 5 0 18 301 11 85 203 7 99 Aluminum 4 3 335 13 19 270 10 63 45 1 77 19 0 75 5 0 2 315 12 4 250 9 84 Stainless steel 335 13 19 270 10 63 45 1 77 19 0 75 5 0 2 315 12 4 250 9 84 15 0 Al...

Страница 13: ...tance Otherwise proceed with unpacking Keep the original packing material in case you must return the monitor for repair or transport it to another location The monitors ship with the following items...

Страница 14: ...tudes up to 2000 m 6561 ft without derating This equipment is considered Group 1 Class A industrial equipment according to EN 61326 1 Without appropriate precautions there can be potential difficultie...

Страница 15: ...he monitors can operate in a surrounding air temperature range of 0 50 C 32 122 F The surrounding air temperature must not exceed the maximum temperature for your monitor especially when the monitor i...

Страница 16: ...B port for installation and maintenance purposes In the U S all wiring must be in accordance with Class I Division 2 wiring methods of Article 501 of the National Electrical Code and in accordance wit...

Страница 17: ...r allow air passages to become obstructed Hot air rises The temperature at the top of the enclosure is often higher than the temperature in other parts of the enclosure especially if air is not circul...

Страница 18: ...d quantity see Figure 5 on page 19 Safety glasses Panel Mounting the Monitor Perform the following steps to install the monitor in the panel cutout 1 Remove all electrical power from the panel before...

Страница 19: ...amage Rockwell Automation assumes no responsibility for water or chemical damage to the monitor or other equipment within the enclosure because of improper installation I O Ports 1 8 7 2 4 5 6 3 All B...

Страница 20: ...type for fixed laying min bend radius 50 4 mm 2 in 6300V 40RVLFIXED Cable 40 m 131 2 ft Cat 5e SF UTP type for fixed laying min bend radius 50 4 mm 2 in 6300V 50RVLFIXED Cable 50 m 164 ft Cat 5e SF U...

Страница 21: ...nstall the eyelet terminal and washers to the ground screw in the sequence at right 5 Tighten the ground screw to the monitor chassis Monitor Display Power Consumption W Max 1 Monitor Display Power Co...

Страница 22: ...chassis 3 Open the power connector assembly kit that ships with the monitor A in Figure 6 4 Insert the cable tie through the slots of the appropriate connector clamp B in Figure 6 5 Strip the end of e...

Страница 23: ...ered Monitors Operate VersaView 6300M AC powered monitors in an industrial or control room environment that uses some form of power isolation from the public low voltage mains To connect AC power to t...

Страница 24: ...isplay OSD Buttons The light emitting diodes LEDs on the front bezel and monitor chassis show the video signal status Use the OSD buttons on the monitor chassis to enter navigate and adjust various di...

Страница 25: ...fixed resolution devices The image looks best when the monitors operate at their native resolution However the monitors have advanced scaling capabilities to make the display look as good as possible...

Страница 26: ...perly the screen can be difficult to read and use of this screen could result in a potentially hazardous outcome Do not use the LCD touch screen under these circumstances The design of the system must...

Страница 27: ...or the other three red circles as they appear in each corner of the screen 6 A confirmation box appears when the calibration is complete Click OK 7 On Tools press Draw Test 8 With your finger draw on...

Страница 28: ...iption Color Function 1 Video signal LED Green Correct video signal input Yellow No video signal 2 Increase the value of the selected control or selects the next menu item 3 Decreases the value of the...

Страница 29: ...e of the monitor default is 5700K Red Adjust the red hue of the monitor from 1 to 100 default is 50 Green Adjust the green hue of the monitor from 1 to 100 default is 50 Blue Adjust the blue hue of th...

Страница 30: ...one or for daylight savings time Phase Adjust the signal timing of the monitor to match that of the graphics card Aspect ratio Resizes the aspect ratio so that any image fits or fills the display scre...

Страница 31: ...ater to clean any monitor labels Clean All Vent Holes Perform the following steps to clean all VersaView 6300M monitors 1 Disconnect power from the monitor at the power source 2 Disconnect all periphe...

Страница 32: ...2 5 1 Salt solution 3 10 Sulfuric acid 5 2 Toluene 1 Acetaldehyde Acetic acid 50 Acteone Acetonitrile Alkalicarbonate Ammonia 32 Ammonium chloride 10 Benzene Bichromate Blown caster oil Cutting oil Ca...

Страница 33: ...h frequency rate are selected 1 On the Windows desktop right click and select Display Settings 2 Scroll down to Scale and Layout Verify that the recommended display resolution is chosen from the pull...

Страница 34: ...Most computers and monitors contain heavy metals that can contaminate the earth Therefore check with local health and sanitation agencies for ways to dispose monitor equipment safely IMPORTANT Do not...

Страница 35: ...Rockwell Automation Publication 6300M UM001A EN P December 2021 35 VersaView 6300M Panel and VESA Monitors User Manual Notes...

Страница 36: ...edgebase articles rok auto knowledgebase Local Technical Support Phone Numbers Locate the telephone number for your country rok auto phonesupport Literature Library Find installation instructions manu...

Отзывы: