140
Rockwell Automation Publication 6000-UM002G-EN-P - August 2022
Appendix E Spare Parts Storage
Control Equipment and
Boards Connection
Guidelines
Control Unit
Figure 72 - DB Board
Energize all boards simultaneously
1. Plug the DT, AT, and PWM boards into their respective slots as shown in
2. Connect the multichannel variable DC source with current limiting
functionality to DC input terminals P1 and P2 of the DB Board, according
to
3. Use 1.3 mm
2
(16 AWG) wire to connect the devices.
DC input terminals
Phase A PWM slot
Phase B PWM slot
Phase C PWM slot
CPU Board slot
AT Board slot
DT Board slot
P1 terminal
6 pins
P2 terminal
6 pins
P3 terminal
4 pins
Table 16 - Power Interface and Distribution for Control Unit
Terminal Pin Symbol
Description
Power
Tolerance
Current
Requirements
(A)
Power (W)
CPU PWM * 3
DT
AT
P1
1
+5V
Digital power
±5%
2.48
3
6.9
2.5
2
M1
Digital ground
3
-15V
Analog power
±5%
0.046
0.03 0.2
4
M5
Analog ground
5
+15V
Analog power
0.106
0.03 0.5
6
PE
Safe ground
P2
1
24V1
HMI power
±5%
2
M2
3
24V2
Redundance
4
M3
5
24V3
For PLC and DT
±5%
0.56
3.95 9.6
6
M4
WARNING:
Do not apply any voltage until all boards are plugged into the
DB Board.
Содержание Allen-Bradley PowerFlex 6000
Страница 10: ...10 Rockwell Automation Publication 6000 UM002G EN P August 2022 Preface Notes ...
Страница 82: ...82 Rockwell Automation Publication 6000 UM002G EN P August 2022 Chapter 4 Parameters and Function Codes Notes ...
Страница 134: ...134 Rockwell Automation Publication 6000 UM002G EN P August 2022 Appendix C Preventative Maintenance Schedule Notes ...
Страница 136: ...136 Rockwell Automation Publication 6000 UM002G EN P August 2022 Appendix D Torque Requirements Notes ...
Страница 148: ...148 Rockwell Automation Publication 6000 UM002G EN P August 2022 Appendix E Spare Parts Storage Notes ...