Rockwell Automation Publication 20P-TD001K-EN-P - January 2021
35
PowerFlex DC Drive and Field Controller Technical Data
Frame D Field Circuit Terminal Block Location
Frames A…C Field Circuit Wire Sizes and Terminal Specifications
Terminals
Wire Size and Type
(1)
(1) For more information, see Cable and Wiring Recommendations in the PowerFlex Digital DC Drive User Manual, publication
Tightening Torque
N•m (lb•in)
U1, V1, C1, D1
24…10 AWG/kcmils
0.5…0.8 (4.4…7.1)
Frame D Field Circuit Wire Sizes and Terminal Specifications
Drive Current Rating Code
(1)
(1) See
PowerFlex DC Drive Catalog Number Explanation on page 6
, positions 8, 9 and 10 for corresponding drive Hp rating, armature Amp rating, and field Amp rating.
Terminals
Wire Size
(2)
(2) For more information, see Cable and Wiring Recommendations in the PowerFlex Digital DC Drive User Manual, publication
Tightening Torque
N•m (lb•in)
230V
460V
575V
690V
875
830
810
678
U1, V1, C1, D1
6 AWG
4.0 (35.4)
1K0
996
1K0
791
—
—
1K2
904
1K3
1K0
1K6
—
1K1
—
1K1
2 AWG
1K3
1K2
1K4
1K4
—
1K5
Bottom of Drive, Left Side
Top of Drive, Left Side
Shown with control cover removed.
Remove control cover to access terminals.
Wire routing hole
Cable
clamp
AC input for field is at
top of fuse holder
(marked FU1, FV1)