Rockwell Automation Publication 20P-TD001K-EN-P - January 2021
15
PowerFlex DC Drive and Field Controller Technical Data
C
495
495
404.4
300
1321-3R500-B
223.7 (300)
100-E460
11
667
667
544.9
400
1321-3R600-B
298.3 (400)
100-E580
11
D
830
830
678.1
500
1321-3R750-B
372.8 (500)
100-E750
996
996
813.7
600
1321-3R850-B
447.4 (600)
100-E860
11
1K1
1162
949.4
700
1321-3R1000-B
552 (700)
100-E1060
1K3
1328
1085.0
800
2 x1321-3R600-B
596.6 (800)
1K4
1494
1220.6
900
2 x1321-3R600-B
671.1 (900)
(1) To order with built in terminal lugs, add the letter “
L
” to the end of the catalog number (example:
100-E116
11L
).
(2) The catalog number as listed is incomplete. See IEC Contactor Specifications Technical Data, publication
, to select coil voltage and optional PLC interface terminals.
PowerFlex DC Drives – 575V AC Input
Frame
Drive Current Rating
Code
DC amps
AC Line amps
Hp
IP00 (Open Style)
Line Reactor Cat No.
Line Reactor kW (Hp) AC Input Contactor Cat.
No.
B
067
67.5
55.1
50
1321-3R55-B
37 (50)
100-C60D10
101
101.25
82.7
75
1321-3R100-B
56 (75)
100-C85D10
135
135
110.3
100
1321-3R130-B
75 (100)
100-E116
x
11
(1)
(2)
(1) To order with built in terminal lugs, add the letter “
L
” to the end of the catalog number (example:
100-E116
11L
).
(2) The catalog number as listed is incomplete. See IEC Contactor Specifications Technical Data, publication
, to select coil voltage and optional PLC interface terminals.
270
270
220.6
200
1321-3RB250-B
149 (200)
100-E305
11
405
405
330.9
300
1321-3RB320-B
224 (300)
100-E370
C
540
540
441.2
400
1321-3R500-B
298 (400)
100-E460
11
675
675
551.5
500
1321-3R600-B
373 (500)
100-E580
11
D
810
810
661.8
600
1321-3R750-B
447 (600)
100-E750
1K0
1080
882.4
800
1321-3R1000-B
597 (800)
100-E1060
11
1K2
1215
992.7
900
1321-3R1000-B
671 (900)
100-E1060
11
1K3
1350
1103.0
1000
2 x 1321-3R600-B
746 (1000)
(3)
(3) No AC Input contactor available for this drive rating - must be sourced locally.
1K6
1687.5
1378.7
1250
2 x 1321-3R750-B
—
PowerFlex DC Drives – 690V AC Input Drives
Frame
Drive Current Rating
Code
DC amps
AC Line amps
Hp
IP00 (Open Style)
Line Reactor Cat No.
Line Reactor kW (Hp) AC Input Contactor Cat.
No.
C
452
452
369
400
1321-3R500-C
—
100-E460
11
(1)
(1) The catalog number as listed is incomplete. See IEC Contactor Specifications Technical Data, publication
, to select coil voltage and optional PLC interface terminals.
565
565
462
500
1321-3R600-C
100-E580
11
D
678
678
554
600
1321-3R750-C
100-E580
11
791
791
646
700
1321-3R750-C
100-E750
904
904
739
800
1321-3R1000-C
100-E750
1K0
1017
831
900
1321-3R1000-C
100-E860
11
1K1
1130
923
1000
2 x 1321-3R600-C
100-E1060
11
1K2
1243
1016
1100
2 x 1321-3R600-C
100-E1060
11
1K4
1412.5
1154
1250
2 x 1321-3R750-C
(2)
(2) No AC Input contactor available for this drive rating - must be sourced locally.
1K5
1582
1292
1400
2 x1321-3R750-C
PowerFlex DC Drives – 460V AC Input (Continued)
Frame
Drive Current
Rating Code
DC amps
AC Line amps
Hp
IP00 (Open Style)
Line Reactor Cat No.
Line Reactor kW (Hp)
AC Input
Contactor Cat. No.