28
Rockwell Automation Publication 2198-RM005A-EN-P - October 2020
Chapter 2 Connectors
Kinetix 5300 Servo Drive
Connector Locations
The connectors of the Kinetix 5300 servo drive are shown in
.
Figure 8 - Kinetix 5300 Connector Locations
I/O Connector and Auxiliary
Feedback Pinouts
This section describes the I/O and Auxiliary Feedback Connector pin
assignments for the Kinetix 350 servo drive and the Kinetix 5300 servo drive.
See
for locations of connectors on your Kinetix 350 drive. See
for locations of connectors on your Kinetix 5300 drive.
There is no separate auxiliary feedback connector used with the Kinetix 350 or
Kinetix 5300 drives. The auxiliary encoder signal is wired using the I/O
connector.
Item
Description
Item
Description
Item
Description
1
Motor cable shield clamp
7
Zero-stack mounting tab/cutout
13
Motor brake connector
2
Motor feedback (MFB) connector
8
Four-character status display
14
Ground terminal
3
Digital inputs and auxiliary feedback
connector
9
Navigation pushbuttons
15
Shunt resistor connector
4
Ethernet (PORT1) RJ45 connector
10
Link speed status indicators
16
AC mains input power connector
5
Ethernet (PORT2) RJ45 connector
11
Link/Activity status indicators
17
24V control input power connector
6
Module and Network status indicators
12
Motor power connector
18
Safe Torque Off (STO) connector
18
17
16
15
L3
L2
L1
1
8
2
3
11
4
5
9
10
14
6
7
13
12
L3
L2
L1
24+
DC+
SH
24-
SB+
SB-
S1
SC
S2
7
2
1
2
1
MOD NET
MBRK
W
V
U
1
10
1
2
MFB
SELECT
BACK
NEXT
KINETIX
5300
DANGER
Elec tric shock
risk . Power
off and wait
5 minutes.
U
V
W
SB+
SB-
S1
SC
S2
Kinetix 5300 Drive, Front View
(2198-C1004-ERS drive is shown)
Kinetix 5300, Top View
(2198-C1004-ERS drive is shown)
Shared-bus 24V Input
Wiring Connector
Kinetix 5300, Bottom View
(frame 2 and 3 drives only)
Cooling Fan