Rockwell Automation Publication 2198-RM005A-EN-P - October 2020
13
Replacement Considerations Chapter 1
Power Specifications
This section provides the power specifications for the Kinetix 350 and Kinetix
5300 servo drives.
list the power specifications and requirements for the
Kinetix 350 servo drives.
Table 8 - Kinetix 350 Drives (Single-phase) Power Specifications
Attribute
2097-V31PR0-LM
2097-V31PR2-LM
2097-V32PR0-LM
2097-V32PR2-LM
2097-V32PR4-LM
AC input voltage
70…132V rms single-phase
(120V nom) voltage-doubler mode
80…264V rms single-phase (240V nom)
80…264V rms single-phase (240V nom)
AC input frequency
48…62 Hz
Main AC input current
(1)
Rms (nom) 120V input (voltage-doubler)
Inrush (0-pk) Max 120V input
Rms (nom) 120/240V input
Inrush (0-pk) max 240V input
9.70 A
1.15 A
5.0 A
1.1 A
15.0 A
1.15 A
8.6 A
1.1
5.0 A
136 A
8.6 A
2.3 A
15.0 A
2.3 A
Integrated AC line filter
No
No
Yes
Yes
Yes
Continuous output current (rms)
2.0 A
4.0 A
2.0 A
4.0 A
8.0 A
Continuous output current (0-pk)
2.8 A
5.7 A
2.8 A
5.7 A
11.3 A
Peak output current (rms)
(2)
6.0 A
12.0 A
6.0 A
12.0 A
24.0 A
Peak output current (0-pk)
8.5 A
17.0 A
8.5 A
17.0 A
39.9 A
Continuous power output @ 240V nom or 120V
(voltage-doubler mode)
(3)
0.40 kW
0.80 kW
0.40 kW
0.80 kW
1.70 kW
Shunt On
390V DC
Shunt Off
375V DC
Overvoltage
430V DC
Short-circuit current rating
100,000 A (rms) symmetrical
(1)
Kinetix 350 drive modules are limited to 1 AC main power cycling per every 2 minutes.
(2) Peak RMS current allowed for up to 2 seconds with a 50% duty cycle.
(3) Nominal continuous power output (kW) applies to 240V AC drives. Value is approximately one-half of this kW rating when using 120V AC.
Table 9 - Kinetix 350 Drives (single-phase and three-phase) Power Specifications
Attribute
2097-V33PR1-LM
2097-V33PR3-LM
2097-V33PR5-LM
2097-V33PR6-LM
AC input voltage
80…132V rms single-phase (120V nom)
80…264V rms single-phase (240V nom)
80…264V rms three-phase (240V nom)
AC input frequency
48…62 Hz
Main AC input current
(1)
Rms (nom) 120V input (voltage doubler)
Inrush (0-pk) max 120V input
Rms (nom) 120/240V input
Inrush (0-pk) max 240V input
5.0 A
68.0 A
3.0 A
136 A
8.6 A
1.15 A
5.0 A
2.3 A
15.0 A
1.15 A
8.7 A
2.3 A
24.0 A
5.65 A
13.9 A
11.3 A
Integrated AC line filter
No
No
No
No
Continuous output current (rms)
2.0 A
4.0 A
8.0 A
12.0 A
Continuous output current (0-pk)
2.8 A
5.7 A
11.3 A
17.0 A
Peak output current (rms)
(2)
6.0 A
12.0 A
24.0 A
36.0 A
Peak output current (0-pk)
8.5 A
17.0 A
33.9 A
50.9 A
Continuous power output @ 240V nom or 120V
(voltage-doubler mode)
(3)
0.50 kW
1.00 kW
2.00 kW
3.00 kW
Shunt On
390V DC
Shunt Off
375V DC
Overvoltage threshold
430V DC
Short-circuit current rating
100,000 A (rms) symmetrical
(1)
Kinetix 350 drive modules are limited to 1 AC main power cycling per every 2 minutes.
(2) Peak RMS current allowed for up to 2 seconds with a 50% duty cycle.
(3) Nominal continuous power output (kW) applies to 240V AC drives. Value is approximately one-half of this kW rating when using 120V AC.