3

1. Record the reading on existing dial.  

2. Remove the 2 side screws on the left and right 

side of the 4” dial. You can now remove the 

old dial from its retainer.  

 

 

 

 

3. With the old (4”) dial removed, keep the 

two mounting brackets on the Left and 

Right side attached to gauge head shown 

below on existing 4” dial gauge. 

Installation Instructions for e-Dial™

2

2

Note:  For 8” dials remove all three existing 

brackets attached to the head and install two 

4” dial brackets (0093s00001; sold separately) 

with 2 screws (0040-00413) each bracket.  You 

may use 4 of the 6 screws from removal of 

existing dial brackets for 8” dial.

3

3

4. Provided with the e-Dial™ are two metal 

standoffs. Screw the standoffs on the 

existing mounting bracket holes where the 

4” dial was mounted on. 

5. Once the new standoffs are installed the 

e-Dial™ may be fitted in place over the 

standoffs. Torque the e-Dial™ screws to 

22 lbf·ft (29.8 N·m) shown to complete 

installation.   

6. Once the e-Dial™ is powered on after 

properly connecting to safety barrier 

(Refer to safety barrier installation guide) 

and power source, compare the new 

Digital Gauge Indicator reading to recorded 

readings or estimated tank contents. If the 

new DGI is not correct (+5%), the DGI may 

need adjustment.

5

5

The Measure of Excellence

e-Dial™ P/N: 6317-00001

    Note:  For 8” Dials, remove the three 

screws on the three brackets attached to 

the existing dial, then remove old dial.

Содержание 6317-00001

Страница 1: ...User Manual...

Страница 2: ...The Measure of Excellence e Dial P N 6317 00001 ii...

Страница 3: ...ty Barrier General Information Features Pre installed 5ft 1 5m cable for battery power input Intrinsically Safe Electrical design Supply Voltage 12 24 VDC Max Input Current 120mA Output Voltage Typica...

Страница 4: ...packed in a cardboard box with a sticker indicating the model the main dimensions of the gauge the mounting position and tank dimensions for which the gauge has been manufactured and the product inte...

Страница 5: ...for 8 dial 3 3 4 Provided with the e Dial are two metal standoffs Screw the standoffs on the existing mounting bracket holes where the 4 dial was mounted on 5 Once the new standoffs are installed the...

Страница 6: ...arrier module to be installed in a nonhazardous location per SD 581 The safety barrier comes with 5ft 1 5m of cable preinstalled This is the power input for the device e Dial comes with a minimum 24ft...

Страница 7: ...pment references neutral as earth The end user shall ensure that there is no potential difference between the neutral connections between the e Dial and e Dial s Barrier L quipement fait r f rence au...

Страница 8: ...easurement Control and Laboratory Use Part 1 General Requirements Note For Canada ordinary locations listing certification Hazardous Locations Safety Standards IEC 60079 0 2017 Explosive atmospheres P...

Страница 9: ...7 DS 1857 Related Drawing Customer Service Toll Free 888 723 5549 Revision A 11 30 2020 Rochester Gauges LLC 11616 Harry Hines Blvd Dallas TX 75229...

Страница 10: ...for use in Class I Division 1 Groups C and D T4 or Zone 0 Group IIB T4 Hazardous Locations under the certification schemes and ratings noted below IECEx Global Certification e Dial Barrier Ex ia Ga II...

Страница 11: ...assessment of electrical and electronic products with respect to the restriction of hazardous substances Step Item e Dial Barrier e Dial System a Equipment group Groups C D Group IIB Groups C D Group...

Страница 12: ...sion A 11 30 2020 Rochester Gauges LLC Customer Service Toll Free 888 723 5549 11616 Harry Hines Blvd P O Box 29242 Dallas TX 75229 For more information visit rochestergauges com info rochestergauges...