background image

9

CE Compliance section:

A.-Electromagnetic Compatibility

1.  EN 61000-6-2:2005 - Electromagnetic compatibility (EMC) - Part 6-2: Generic 

standards - Immunity for industrial environments IEC 61000-6-2:2005

2. EN 61000-6-4:2007 - Electromagnetic compatibility (EMC) - Part 6-4: Generic 

standards - Emission standard for industrial environments IEC 61000-6-4:2006

B. -Restriction of hazardous substances in electrical and electron equipment

1.  EN 50581:2012 - Technical documentation for the assessment of electrical and 

electronic products with respect to the restriction of hazardous substances

Step Item

e-Dial Barrier

e-Dial

System

a)

Equipment group

Groups C&D 

(Group IIB)

Groups C&D 

(Group IIB)

Groups C&D (Group IIB)

b)

Level of protection Ex ia

Ex ia

Ex ia

c)

Temperature 

classification

N/A

T4

T4

d)

Ambient 

temperature

−40°C to +60°C

−40°C to +80°C -40°C to +60°C – Barrier

-40°C to +80°C – e-Dial

e)

Parameter comparison

Voltage

Uo: 9.45 V

Ui: 9.45 V

Current

Io: 444 mA

Ii: 444 mA

Power

Po: 1.05 W

Pi: 1.05 W

f)

Cable parameters

Capacitance

Co: 27 µF

Ci: 15.12 µF

Cc < 11.4 µF

Inductance

Lo: 721.44 µH

Li: 4.7 µH

Lc < 716.3 µH

L/R ratio

N/A

N/A

N/A

g)

Earthing

Grounded

Grounded

Grounded

Содержание 6317-00001

Страница 1: ...User Manual...

Страница 2: ...The Measure of Excellence e Dial P N 6317 00001 ii...

Страница 3: ...ty Barrier General Information Features Pre installed 5ft 1 5m cable for battery power input Intrinsically Safe Electrical design Supply Voltage 12 24 VDC Max Input Current 120mA Output Voltage Typica...

Страница 4: ...packed in a cardboard box with a sticker indicating the model the main dimensions of the gauge the mounting position and tank dimensions for which the gauge has been manufactured and the product inte...

Страница 5: ...for 8 dial 3 3 4 Provided with the e Dial are two metal standoffs Screw the standoffs on the existing mounting bracket holes where the 4 dial was mounted on 5 Once the new standoffs are installed the...

Страница 6: ...arrier module to be installed in a nonhazardous location per SD 581 The safety barrier comes with 5ft 1 5m of cable preinstalled This is the power input for the device e Dial comes with a minimum 24ft...

Страница 7: ...pment references neutral as earth The end user shall ensure that there is no potential difference between the neutral connections between the e Dial and e Dial s Barrier L quipement fait r f rence au...

Страница 8: ...easurement Control and Laboratory Use Part 1 General Requirements Note For Canada ordinary locations listing certification Hazardous Locations Safety Standards IEC 60079 0 2017 Explosive atmospheres P...

Страница 9: ...7 DS 1857 Related Drawing Customer Service Toll Free 888 723 5549 Revision A 11 30 2020 Rochester Gauges LLC 11616 Harry Hines Blvd Dallas TX 75229...

Страница 10: ...for use in Class I Division 1 Groups C and D T4 or Zone 0 Group IIB T4 Hazardous Locations under the certification schemes and ratings noted below IECEx Global Certification e Dial Barrier Ex ia Ga II...

Страница 11: ...assessment of electrical and electronic products with respect to the restriction of hazardous substances Step Item e Dial Barrier e Dial System a Equipment group Groups C D Group IIB Groups C D Group...

Страница 12: ...sion A 11 30 2020 Rochester Gauges LLC Customer Service Toll Free 888 723 5549 11616 Harry Hines Blvd P O Box 29242 Dallas TX 75229 For more information visit rochestergauges com info rochestergauges...

Отзывы: