background image

The Measure of Excellence

e-Dial™ P/N: 6317-00001

6

•  WARNING

 - POTENTIAL ELECTROSTATIC CHARGING HAZARD  

Caution must be used when handling or cleaning products so there is no static 

charge buildup. Do not wipe off the e-Dial™ sensor with dry cloth. Use only water 

damp cloth and allow to air dry for cleaning device. Do not use or install in high 

charge areas. See IEC60079-32-1 for further information.

 

•  AVERTISSEMENT

 - RISQUE DE CHARGE ÉLECTROSTATIQUE POTENTIEL 

Il faut être prudent lors de la manipulation ou du nettoyage des produits afin qu’il 

n’y ait pas d’accumulation de charge statique. N’essuyez pas le capteur e-Dial™ avec 

un chiffon sec. Utilisez uniquement un chiffon humide et laissez sécher à l’air pour 

nettoyer l’appareil. Ne pas utiliser ou installer dans des zones de charge élevée. Voir 

IEC 60079-32-1 pour plus d’informations.

 

List of safety Related info which is critical for safe operation.

Safety Specifications 

Ordinary Locations Safety Standards

Conforms to UL STD 61010-1 

Ed. 3

Electrical Equipment for Measurement, Control, and Laboratory Use; 

Part 1: General Requirements

*Note: For USA ordinary locations listing certification
Certified to CSA STD C22.2 

#61010-1-12 Ed.3

Electrical Equipment for Measurement, Control, and Laboratory Use; 

Part 1: General Requirements

*Note: For Canada ordinary locations listing certification

Hazardous Locations Safety Standards

IEC 60079-0: 2017

Explosive atmospheres - Part 0: Equipment - General requirements

*Note: For IECEx Certification

IEC 60079-11: 2011 + C1: 2012

Explosive atmospheres - Part 11: Equipment protection by intrinsic 

safety "i"

*Note: For IECEx Certification
IEC 60079-25: 2010 Ed 2. 

Explosive atmosphere – Part 25: Intrinsically safe electrical systems

*Note: For IECEx Certification
EN 60079-0: 2018

Explosive atmospheres - Part 0: Equipment - General requirements

*Note: For ATEX Certification
EN 60079-11:2012

Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" 

*Note: For ATEX Certification
EN 60079-25: 2010

Explosive atmosphere – Part 25: Intrinsically safe electrical system 

*Note: For ATEX Certification
Conforms to UL STD 60079-0 Ed.7

Explosive atmospheres - Part 0: Equipment - General requirements

*Note: For USA listing certification
Conforms to UL STD 60079-11 

Ed.6

Explosive atmospheres - Part 11: Equipment protection by intrinsic 

safety "i"

*Note: For USA listing certification
Certified to CSA STD C22.2 

#60079-0 Ed.4

Explosive atmospheres - Part 0: Equipment - General requirements

*Note: For Canada listing certification
Certified to CSA STD  C22.2 

#60079-11 Ed.2

Explosive atmospheres - Part 11: Equipment protection by intrinsic 

safety "i"

*Note: For Canada listing certification

Содержание 6317-00001

Страница 1: ...User Manual...

Страница 2: ...The Measure of Excellence e Dial P N 6317 00001 ii...

Страница 3: ...ty Barrier General Information Features Pre installed 5ft 1 5m cable for battery power input Intrinsically Safe Electrical design Supply Voltage 12 24 VDC Max Input Current 120mA Output Voltage Typica...

Страница 4: ...packed in a cardboard box with a sticker indicating the model the main dimensions of the gauge the mounting position and tank dimensions for which the gauge has been manufactured and the product inte...

Страница 5: ...for 8 dial 3 3 4 Provided with the e Dial are two metal standoffs Screw the standoffs on the existing mounting bracket holes where the 4 dial was mounted on 5 Once the new standoffs are installed the...

Страница 6: ...arrier module to be installed in a nonhazardous location per SD 581 The safety barrier comes with 5ft 1 5m of cable preinstalled This is the power input for the device e Dial comes with a minimum 24ft...

Страница 7: ...pment references neutral as earth The end user shall ensure that there is no potential difference between the neutral connections between the e Dial and e Dial s Barrier L quipement fait r f rence au...

Страница 8: ...easurement Control and Laboratory Use Part 1 General Requirements Note For Canada ordinary locations listing certification Hazardous Locations Safety Standards IEC 60079 0 2017 Explosive atmospheres P...

Страница 9: ...7 DS 1857 Related Drawing Customer Service Toll Free 888 723 5549 Revision A 11 30 2020 Rochester Gauges LLC 11616 Harry Hines Blvd Dallas TX 75229...

Страница 10: ...for use in Class I Division 1 Groups C and D T4 or Zone 0 Group IIB T4 Hazardous Locations under the certification schemes and ratings noted below IECEx Global Certification e Dial Barrier Ex ia Ga II...

Страница 11: ...assessment of electrical and electronic products with respect to the restriction of hazardous substances Step Item e Dial Barrier e Dial System a Equipment group Groups C D Group IIB Groups C D Group...

Страница 12: ...sion A 11 30 2020 Rochester Gauges LLC Customer Service Toll Free 888 723 5549 11616 Harry Hines Blvd P O Box 29242 Dallas TX 75229 For more information visit rochestergauges com info rochestergauges...